Investigation of required modifications of the manufactured TRR DPC for transport and storage of two-year cooled spent fuel assemblies
محل انتشار: فصلنامه فیزیک و مهندسی پرتو، دوره: 7، شماره: 2
سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 41
فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_RPE-7-2_007
تاریخ نمایه سازی: 21 آبان 1405
چکیده مقاله:
Dual-purpose cask (DPC) is used for transporting and interim storage of spent fuel assemblies, since such casks are an attractive option due to their flexibility and economy efficiency. In point of economical view, construction of high-capacity DPC is more suitable. The cask could be used to transport the spent fuel assemblies of long cooling time with its full capacity. At emergency situations the same cask potentially could be used to transport the spent fuels with short cooling time using some modifications inside the canister. The present study would investigate the highest capacity of Tehran Research Reactor (TRR) DPC for transport and storage of ۲-year cooled spent fuel assemblies. MCNPX۲.۷.۰ computational code was used to calculate the DPC body maximum gamma and neutron dose rates. The obtained results showed that maximum six ۲-year cooled SFAs of TRR could be transported by the present DPC. Moreover, filling the empty places of canister with carbon-steel shield blocks, some modifications on the cask door and floor is needed to pass the determined gamma dose rate limit (۲ mSv.h-۱). By adding ۶ cm thick carbon-steel on the DPC door and its bottom the goal is obtained while the modifications increase the cask weight about ۱ ton.
کلیدواژه ها:
نویسندگان
- -
Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute, Tehran, Iran
- -
Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute, Tehran, Iran
- -
Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute, Tehran, Iran
- -
Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :