Determination of the neutron and gamma dose distribution due to the operation of vertical neutron beam lines

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 34

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_RPE-7-3_006

تاریخ نمایه سازی: 21 آبان 1405

چکیده مقاله:

In this study, the effect of external neutron beam tubes of MNSR research reactor on increasing the neutron and gamma dose rates in different zones of the reactor building was investigated and the dose distribution was determined through calculation and measurements. This study was conducted to investigate the radiation protection conditions at different operation conditions of these beam tubes and to ensure the radiation safety of the reactor operators and researchers. The results showed that when both beam tubes are operated simultaneously, the average total dose rate in the reactor hall, pneumatic room and corridors increases to ۴.۵۸ μSv.h-۱, ۱.۷ μSv.h-۱ and ۴.۹ μSv.h-۱, respectively at the maximum power of reactor, i.e. ۳۰ kW. The major part of the dose rate of neutrons and gamma rays distributed in the environment is caused by the neutron radiography channel, and more than ۸۰% of the dose rate is related to gamma rays. On the other hand, the performance of the neutron radiography beam tube radiation protection system showed that even when the reactor is at its maximum power and these beam tubes are inactive, the total dose at the edges of the reactor pool is about ۲% of the annual dose limit. This indicates that the radiation protection of the beam tube has a good performance in preventing the increase in the dose rate when the beam tube is deactivated.

کلیدواژه ها:

نویسندگان

- -

Reactor and Nuclear Safety Research School, Nuclear Science and Technology Research Institute, AEOI, Iran

- -

Reactor and Nuclear Safety Research School, Nuclear Science and Technology Research Institute, AEOI, Iran

- -

Department of Physics, Isfahan University of Technology, Isfahan, Iran

- -

Department of Physics, Isfahan University of Technology, Isfahan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Asgari, A., Hosseini, S. A., Dastjerdi, M. H. C., et ...
  • Asgari, A., Hosseini, S. A., Dastjerdi, M. H. C., et ...
  • Asgari, A., Hosseini, S. A., Dastjerdi, M. H. C., et ...
  • Aswal, D. K., Sarkar, P. S., and Kashyap, Y. S., ...
  • Bagherzadeh, M., Dastjerdi, M. C., and Mokhtari, J. (۲۰۲۳a). Feasibility ...
  • Bagherzadeh, M., Karimi, M., Choopan Dastjerdi, M. H., et al. ...
  • Casali, F., Chirco, P., and Zanarini, M. (۱۹۹۵). Advanced imaging ...
  • Dastjerdi, M. C., Mokhtari, J., Asgari, A., et al. (۲۰۱۹). ...
  • Dastjerdi, M. C., Mokhtari, J., Toghyani, M., et al. (۲۰۲۳). ...
  • Dastjerdi, M. H. C., Khalafi, H., Kasesaz, Y., et al. ...
  • De Beer, F. C. (۲۰۱۵). Neutron-and X-ray radiography/tomography: Non-destructive analytical ...
  • Fujine, S., Yoneda, K., Mochiki, K. I., et al. (۱۹۹۶). ...
  • Ghasemi, Z., Hassanvand, M., Dastjerdi, M. C., et al. (۲۰۲۳). ...
  • Gholamzadeh, Z., Bavarnegin, E., Ebrahimzadeh, R., et al. (۲۰۲۴). Experimental ...
  • IAEA (۲۰۱۴). Radiation Protection and Safety of Radiation Sources: International ...
  • IAEA (۲۰۲۵). History, Development and Future of SLOW-POKE and MNSR ...
  • International Atomic Energy Agency (۲۰۰۸). Neutron Imaging: A Non-Destructive Tool ...
  • Jafari, M., Jafari, H., Dastjerdi, M. C., et al. (۲۰۲۴a). ...
  • Jafari, M., Jafari, H., Dastjerdi, M. C., et al. (۲۰۲۴b). ...
  • Jafari, M., Jafari, H., Dastjerdi, M. C., et al. (۲۰۲۵a). ...
  • Jafari, M., Jafari, H., Dastjerdi, M. C., et al. (۲۰۲۵b). ...
  • Laurent-Pettersson, M., Delpech, B., and Thellier, M. (۱۹۹۲). The mapping ...
  • Mokhtari, J. and Dastjerdi, M. C. (۲۰۲۳). Development and characterization ...
  • Mokhtari, J., Dastjerdi, M. C., and Soleimani, B. (۲۰۲۳). Improvement ...
  • Mokhtari, J., Faghihi, F., Dastjerdi, M. C., et al. (۲۰۲۰). ...
  • Investigating the emitted dose from small and large out-of-tank irradiation channels of a low power research reactor through calculation and measurement [مقاله ژورنالی]
  • Moslehi, A., Dastjerdi, M. C., Torkzadeh, F., et al. (۲۰۲۲). ...
  • Prince, R. (۲۰۱۲). Radiological Survey and Monitoring Instrumentation. In Radiation ...
  • Rahmati, E., Barough, M. S., Dastjerdi, M. C., et al. ...
  • Svab, E., Mszros, G., Somogyvari, Z., et al. (۲۰۰۴). Neutron ...
  • Tanner, R. J., Molinos, C., Roberts, N. J., et al. ...
  • Vatani, M., Hassanvand, M., Mokhtari, J., et al. (۲۰۲۳). Design ...
  • نمایش کامل مراجع