Factors Associated with Use of a Posterior Approach and Use of Minimally Invasive Plate Osteosynthesis for Plate and Screw Fixation of Middle Third Humeral Diaphysis Fracture
محل انتشار: مجله استخوان و جراحی عمومی، دوره: 14، شماره: 10
سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 12
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_TABO-14-10_004
تاریخ نمایه سازی: 22 مهر 1405
چکیده مقاله:
Objectives: We sought factors associated with use of a relatively unconventional use of a posterior surgical exposure and fixation for management of middle third humeral diaphysis fractures. Methods: In a scenario-based experiment ۱۱۲ surgeon participants of the Science of Variation Group (SOVG)–an international collaboration of fracture surgeons that study sources of variation in care– viewed ۱۱ sets of radiographs of ۹ middle and ۲ distal third fractures of the humeral diaphysis. The primary response variable was decision to use a posterior surgical approach and fixation. The secondary response variable was additional use of a minimally invasive plate osteosynthesis (MIPO) technique. Logistic regression analysis assessed the impact of gender, continent of practice, years in practice, subspecialty, location of fellowship, volume of fractures treated per year, and location of fracture. Results: Factors associated with recommendation of a posterior approach included ۶-۱۰ years in practice (β ۰.۹۶; ۹۵% CI ۰.۵۵ to ۱.۴) and identifying as a fracture surgeon (β ۰.۴۲; ۹۵% CI ۰.۰۶ to ۰.۷۸). Fracture location in the middle third of the humeral shaft was associated with decreased likelihood to recommend a posterior approach (β -۲.۲; ۹۵% CI -۲.۶ to -۱.۷) as was practicing for ۲۱ to ۳۰ years (β -۰.۶۵; ۹۵% CI -۱.۰ to -۰.۲۵). Factors associated with use of a MIPO technique included practicing outside of the US and Europe (β ۰.۹۱ ۹۵% CI ۰.۴۷ to ۱.۳) and ۲۱-۳۰ years of practice (β CI ۰.۷۱ ۹۵% CI ۰.۲۰ to ۱.۲) (all p < ۰.۰۵). Conclusion: The observed association between distal third fracture location and posterior exposure for plate and screw fixation of a diaphyseal humerus fracture suggests that a posterior plate location may be a marker of relative surgeon unfamiliarity with fracture fixation surgery in this region. Level of evidence: IV
کلیدواژه ها:
نویسندگان
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
- -
Dell Medical School, University of Texas at Austin; Austin TX, USA
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :