چکیده مقاله:
A highly selective potentiometric method for the determination of tenoxicam (TEX) was developed based on molecularly imprinted polymer (MIP) membrane electrodes. This study contributes to the field of analytical chemistry by designing advanced electrochemical sensors for pharmaceutical analysis. The tenoxicam-imprinted polymers (TEX-MIPs) were synthesized using tenoxicam as the template molecule, allyl chloride as the functional monomer, trimethylolpropane triacrylate (TMPTA) as the cross-linking agent, and benzoyl peroxide (BP) as the radical initiator. Poly(vinyl chloride) (PVC)-based membranes were fabricated incorporating various plasticizers, namely oleic acid (O.A), paraffin (PRF), tri-butyl phosphate (TBP), and di-butyl sebacate (DBS), and subsequently employed to construct potentiometric electrochemical sensors. The fabricated TEX-MIP electrodes exhibited near-Nernstian slopes of ۴۲.۶-۵۲.۷ mV per decade over a linear concentration range of ۱.۰ × ۱۰⁻⁵ to ۱.۰ × ۱۰⁻¹ M. These analytical characteristics demonstrate the suitability of the proposed electrochemical sensing platform for quantitative analysis in modern analytical chemistry. The sensors demonstrated stable and reproducible responses within a wide pH range (۳–۹). Selectivity studies conducted in the presence of common pharmaceutical excipients, including benzoic acid, sodium benzoate, methyl paraben, and glucose, confirmed the high selectivity of the proposed electrodes toward tenoxicam. The obtained results indicate that TEX-MIP-based membrane electrodes provide a reliable, sensitive, and selective electrochemical analytical platform for the potentiometric determination of tenoxicam in pharmaceutical formulations and environmental samples.
کلیدواژه ها:
Tenoxicam ، Molecularly imprinted polymers ، Pharmaceutical and environmental samples ، Electrochemical sensors ، Ion-selective electrodes
نویسندگان
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :