Background: Anemia is a prevalent hematological disorder associated with substantial morbidity among hospitalized patients. This study aimed to evaluate the diagnostic accuracy of non-contrast cardiac computed tomography (CT) attenuation measurements obtained from different cardiac regions for detecting anemia and grading its severity. Methods: This cross-sectional study included ۳۳۶ patients who underwent non-contrast thoracic CT imaging. Attenuation values were measured in the left ventricle, right ventricle, interventricular septum, and aortic arch and were compared with hemoglobin levels obtained from complete blood count tests. ROC curve analysis, independent-samples t-tests, Mann-Whitney U tests, one-way ANOVA, and correlation analyses were performed to evaluate diagnostic performance and subgroup differences. Significance was set at P-Value < ۰.۰۵. Results: Aortic arch attenuation demonstrated the highest diagnostic accuracy for overall anemia detection (Area under the curve [AUC] = ۰.۶۶۸; Sensitivity = ۷۱.۳%; Specificity = ۵۵.۹%), followed by left ventricular attenuation (AUC = ۰.۶۳۵; Sensitivity = ۴۴.۰%; Specificity = ۷۶.۵%). Diagnostic performance improved for moderate to severe anemia (AUCs ranging from ۰.۶۹۰ to ۰.۷۵۷), whereas discrimination of mild anemia remained limited (AUCs ≤ ۰.۵۸۹). Attenuation values in the left ventricle, right ventricle, and aortic arch showed significant inverse correlations with hemoglobin levels (Spearman’s rho = -۰.۲۷۵ to -۰.۲۹۷; P-Value < ۰.۰۰۱), while no significant association was observed in the septum. Gender-stratified analyses showed consistent reductions in attenuation among anemic patients of both genders. Conclusion: Non-contrast cardiac CT attenuation measurements showed statistically significant associations with hemoglobin levels but demonstrated limited discriminatory performance for anemia detection, particularly in mild cases. Attenuation values obtained during routine thoracic imaging may provide complementary opportunistic information; however, further validation studies are required before clinical implementation.

نویسندگان

Somayeh Livani

Department of Radiology, Shahid Sayad Shirazi Hospital, Golestan University of Medical Sciences, Gorgan, Iran

Mohammad Mohajertabrizi

Department of Industrial Engineering, Gorgan Faculty of Engineering, Golestan University, Gorgan, Iran

Asma Razman

Clinical Research Development Unit (CRDU), ۵azar Hospital, Golestan University of Medical Sciences, Gorgan, Iran

Mitra Omrani

Department of Radiology, Shahid Sayad Shirazi Hospital, Golestan University of Medical Sciences, Gorgan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • McLean E, Cogswell M, Egli I, Wojdyla D, de Benoist ...
  • Foster M, Nolan RL, Lam M. Prediction of anemia on ...
  • Zhou Q-Q, Yu Y-S, Chen Y-C, Ding B-B, Fang S-Y, ...
  • Desaint P, Bernard C, Contou D. Diagnosing anemia with chest ...
  • Kamel EM, Rizzo E, Duchosal MA, Duran R, Goncalves-Matoso V, ...
  • Zopfs D, Rinneburger M, Pinto Dos Santos D, Reimer RP, ...
  • Abbasi B, Seyed Hosseini M, Moodi Ghalibaf A, Akhavan R, ...
  • Damodaran Kumar U, Arputham NM, Sivalingam SJ, Srinivasan S. Diagnostic ...
  • World Health Organization. Haemoglobin concentrations for the diagnosis of anaemia ...
  • نمایش کامل مراجع