Numerical Simulation of Pressure Pulsation in a Two-stage Double-suction Centrifugal Pump for Ophthalmic Medical Centers

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 19

فایل این مقاله در 13 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JAFM-19-9_007

تاریخ نمایه سازی: 14 مرداد 1405

چکیده مقاله:

In ophthalmic medical centers (OMCs), a major challenge with vibration control is that while the preference for sophisticated diagnostic equipment is very low vibration, centralized cooling systems demand high-capacity pumping power. To reconcile these conflicting needs, in this study, we targeted the hydraulic source of pipeline vibration—the two-stage double-suction centrifugal pump (TDCP). We performed a full-field unsteady simulation based on the Scale Adaptive Simulation (SAS) model for mapping pressure pulsation evolution. Results show a typical double peak type of distribution at the tongues of the transition channel and volute. A critical multi-stage interaction effect is identified: partial load operation (۰.۶Qn) triggers a massive recirculation vortex in the transition channel. This structure generates a high-amplitude, low-frequency (approx. ۲۵ Hz) signal distinct from the blade passing frequency (fBPF), creating a resonance risk for long-distance piping. Conversely, pulsations in the second-stage volute are dominated by rotor–stator interaction (RSI) and scale monotonically with flow rate. We conclude that restricting TDCP operation to near-design conditions (۱.۰Qn) is the most effective strategy for dampening excitation, offering a theoretical basis for low-vibration hospital infrastructure.

نویسندگان

Y. Gong

Department of Ophthalmology, Nanjing First Hospital, Nanjing Medical University, Nanjing, ۲۱۰۰۰۶, China

X. Cao

Department of Ophthalmology, Nanjing First Hospital, Nanjing Medical University, Nanjing, ۲۱۰۰۰۶, China

Y. Wang

School of Electrical and Power Engineering, Hohai University, Nanjing, ۲۱۱۱۰۰, China

Y. Zheng

School of Electrical and Power Engineering, Hohai University, Nanjing, ۲۱۱۱۰۰, China

D. An

Beijing Aerospace Propulsion Institute, China Aerospace Science and Technology Corporation, Beijing, ۱۰۰۱۷۶, China

J. Ma

Department of Ophthalmology, Nanjing First Hospital, Nanjing Medical University, Nanjing, ۲۱۰۰۰۶, China

Y. Liu

Department of Ophthalmology, Nanjing First Hospital, Nanjing Medical University, Nanjing, ۲۱۰۰۰۶, China

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :