Advancing Radiotherapy Precision for Cervical Cancer: Reducing Setup Errors and Optimizing PTV Margins
سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 64
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JOGCR-11-4_008
تاریخ نمایه سازی: 16 تیر 1405
چکیده مقاله:
Background & Objective: Radiotherapy plays a key role in cancer treatment, particularly in the treatment of pelvic cancers like cervical cancer, by delivering targeted radiation to the tumor. The present study was conducted with aim to highlight the significance of addressing setup errors in cervical cancer radiotherapy through the optimization of treatment margins, ultimately aiming to improve both treatment accuracy and patient outcomes.Materials & Methods: This retrospective study was conducted on ۲۰ cervical cancer patients treated between January and September ۲۰۲۴, using knee and foot fixed supports for immobilization. Treatment setups were verified with electronic portal imaging and delivered via an Elekta linear accelerator. Displacement analysis assessed setup errors using bony landmarks, and safety margins were calculated based on ICRU-۶۲ guidelines and Stroom’s and Van Herk’s formulas.Results: The findings revealed systematic errors of up to ۰.۲۲ cm and random errors of ۰.۷۴ cm (X-axis), ۰.۲ cm and ۰.۰۸ cm (Y-axis), and ۰.۱۸ cm and ۰.۰۸ cm (Z-axis). The calculated CTV-PTV margins were ۰.۶۱ cm, ۰.۵۷ cm, and ۰.۵۱ cm along the X, Y, and Z axes (Van Herk’s formula), ۰.۵ cm, ۰.۴۶ cm, and ۰.۴۲ cm (Stroom’s formula), and ۰.۲۳ cm, ۰.۲۲ cm, and ۰.۲ cm (ICRU-۶۲ guidelines). Based on these findings, a ۶ mm safety margin is recommended as optimal.Conclusion: This study demonstrates that image-guided verification using electronic portal imaging improves accuracy, reduces setup errors, and supports the implementation of a ۶ mm safety margin in pelvic radiotherapy, enhancing both treatment precision and patient quality of life.
کلیدواژه ها:
نویسندگان
Ahlam Azalmad
Laboratory of Sciences and Engineering of Biomedicals Biophysics and Health, Higher Institute of Health Sciences, Settat, University Hassan Fisrt, Morocco
Youness Elmaadaoui
ENSAM School of Engineering in Rabat, Mohammed V University, Rabat, Morocco
Mohamed Hilal
Laboratory of Sciences and Engineering of Biomedicals Biophysics and Health, Higher Institute of Health Sciences, University Hassan First, Settat, Morocco
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :