Colocutaneous Fistula Due to Cecum Invasion with Mesh Plug After Inguinal Hernia Repair, Case Report and Literature Review

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 62

متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJHS-12-3_004

تاریخ نمایه سازی: 1 تیر 1405

چکیده مقاله:

Background: Inguinal hernia repair, among the most frequently performed surgical procedures worldwide, is generally associated with low morbidity. However, complications such as mesh migration and erosion into adjacent anatomical structures, although rare, can have significant clinical implications. Full-thickness erosion of mesh into the cecum, resulting in a colocutaneous fistula, represents an exceedingly rare phenomenon.Case Presentation: This report details the case of an ۸۲-year-old male with a prior history of right inguinal hernia repair who presented with persistent fecaloid discharge from the surgical scar following an initial episode of abscess formation and incision and drainage. Advanced imaging modalities identified an enterocutaneous fistula connecting the cecum to the inguinal region. Diagnostic laparoscopy revealed necrosis of a segment of the cecum caused by erosion of a polypropylene mesh plug. The patient underwent laparoscopic hemicolectomy with complete excision of the mesh and subsequent debridement and repair of the inguinal wound. Postoperatively, the patient experienced an uneventful recovery, and the surgical site healed successfully.Conclusion: Clinicians should maintain a high index of suspicion for mesh-related complications, such as erosion and fistula formation, in patients presenting with delayed abscesses or intestinal discharge at prior hernia repair sites. This case underscores the importance of careful patient selection and consideration of alternative techniques in high-risk individuals to minimize the incidence of such rare but serious outcomes.Background: Inguinal hernia repair, among the most frequently performed surgical procedures worldwide, is generally associated with low morbidity. However, complications such as mesh migration and erosion into adjacent anatomical structures, although rare, can have significant clinical implications. Full-thickness erosion of mesh into the cecum, resulting in a colocutaneous fistula, represents an exceedingly rare phenomenon. Case Presentation: This report details the case of an ۸۲-year-old male with a prior history of right inguinal hernia repair who presented with persistent fecaloid discharge from the surgical scar following an initial episode of abscess formation and incision and drainage. Advanced imaging modalities identified an enterocutaneous fistula connecting the cecum to the inguinal region. Diagnostic laparoscopy revealed necrosis of a segment of the cecum caused by erosion of a polypropylene mesh plug. The patient underwent laparoscopic hemicolectomy with complete excision of the mesh and subsequent debridement and repair of the inguinal wound. Postoperatively, the patient experienced an uneventful recovery, and the surgical site healed successfully. Conclusion: Clinicians should maintain a high index of suspicion for mesh-related complications, such as erosion and fistula formation, in patients presenting with delayed abscesses or intestinal discharge at prior hernia repair sites. This case underscores the importance of careful patient selection and consideration of alternative techniques in high-risk individuals to minimize the incidence of such rare but serious outcomes.

نویسندگان

Fakhry Alsadat Anaraky Firooz

Department of Colorectal surgery, school of medicine, Shahid Beheshti University of Medical Sciences, Taleghani hospital, Tehran, Iran.

Hamed Ebrahimibagha

Department of Colorectal surgery, school of medicine, Shahid Beheshti University of Medical Sciences, Modarres hospital, Tehran, Iran.

Adel Zeinalpour

Department of Colorectal surgery, school of medicine, Shahid Beheshti University of Medical Sciences, Modarres hospital, Tehran, Iran.

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Isaia M, Christou D, Kallis P, Koronakis N, Hadjicostas P. ...
  • Murphy J, Misra D, Silverglide B. Sigmoid colonic fistula secondary ...
  • Policarpo F, Rafael AA, Borges MF, Azevedo F. Cecum perforation ...
  • Broderick J, Siegel T. A Case of an Anomalous Tract ...
  • Sekiguchi K, Mizuguchi Y, Mamada Y, Koizumi M, Uchida E. ...
  • Jayamanne H, Williams GL, Stephenson BM. Colocutaneous fistula after left ...
  • Gandhi D, Marcin S, Xin Z, Asha B, Kaswala D, ...
  • Agrawal A, Avill R. Mesh migration following repair of inguinal ...
  • Al-Subaie S, Al-Haddad M, Al-Yaqout W, Al-Hajeri M, Claus C. ...
  • Singh RR, Gupta AK, Shah AS, Singh R, Singh A. ...
  • Cunningham H, Weis J, Taveras L, Huerta S. Mesh migration ...
  • نمایش کامل مراجع