Centrifugal pump,, ">Hydraulic efficiency,, ">Performance prediction,, ">Empirical correlations,, ">Steady-state simulation" >Centrifugal pump,, ">Hydraulic efficiency,, ">Performance prediction,, ">Empirical correlations,, ">Steady-state simulation" >

Development of Empirical Correlations for Centrifugal Pump Performance: Effects of Casing on Hydraulic Efficiency

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 71

فایل این مقاله در 20 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JAFM-19-7_017

تاریخ نمایه سازی: 1 تیر 1405

چکیده مقاله:

The study evaluates the performance of a centrifugal pump by comparing two CFD configurations: an impeller-only model (Model-A) and a full pump model with casing (Model-B). Simulations were carried out using the standard k–ε turbulence model with ۴.۱۶ million computational elements, applying a total pressure inlet and a mass flow outlet as boundary conditions. Flow characteristics such as velocity distribution, static and total pressure, head coefficient, hydraulic loss coefficient, and efficiency were examined to establish empirical correlations between the two configurations. The results indicate that Model-A produces a more uniform velocity field with lower hydraulic losses, while Model-B shows flow recirculation and vortex formation near the volute tongue at low discharge, leading to increased energy dissipation and reduced efficiency. Static pressure results confirm the casing’s contribution to pressure recovery, albeit with added hydraulic losses. The proposed correlations accurately predict full pump performance from impeller-only data within ±۴%, offering a time- and cost-effective approach for centrifugal pump design and optimization.

نویسندگان

A. U. Rehman

Department of Mechanical Engineering, B.B.S. College of Engineering & Technology, Prayagraj,۲۱۱۰۰۳, India

A. R. Paul

Department of Applied Mechanics, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, ۲۱۱۰۰۳, India

A. Jain

Department of Applied Mechanics, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, ۲۱۱۰۰۳, India

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :