EPID-Based Setup Error Correction in Head and Neck Radiotherapy
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 23، شماره: 1
سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 75
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-23-1_005
تاریخ نمایه سازی: 13 خرداد 1405
چکیده مقاله:
Introduction: This study introduces and evaluates a novel optimized averaging method for Electronic Portal Imaging Device (EPID)-based setup corrections, comparing it with conventional approaches. Material and Methods: A total of ۲۸ head and neck cancer patients undergoing conformal radiotherapy were enrolled prospectively. Three EPID-based setup correction methods were compared: no averaging (Method ۱), standard three-fraction averaging (Method ۲), and a new optimized averaging method (Method ۳). Setup errors were quantified in three dimensions, and Clinical Target Volume to Planning Target Volume (CTV-PTV) margins were calculated. Primary outcomes included systematic and random errors, CTV-PTV margin reduction, and the proportion of patients benefiting from each method. Results: Both averaging methods significantly reduced systematic and random errors compared to no averaging (p<۰.۰۵). Mean setup errors decreased to <۱ mm in all directions for Methods ۲ and ۳. CTV-PTV margins were reduced from ۵.۷-۷.۹ mm to ۳.۶-۳.۷ mm, a reduction of ۳۵-۵۰%. The optimized method (Method ۳) reduced mean errors in ۶۴-۶۸% of patients across all directions, compared to ۶۸-۷۱% for Method ۲ relative to Method ۱. Notably, Method ۳ reduced the incidence of gross errors by ۶۷% compared to no averaging. Conclusion: The novel optimized averaging method for EPID-based setup corrections significantly improves setup accuracy in head and neck radiotherapy, outperforming conventional techniques. This approach substantially reduces CTV-PTV margins and the occurrence of gross errors, potentially allowing for more conformal dose distributions and reduced toxicity. These findings have important implications for improving treatment precision and outcomes in head and neck cancer radiotherapy.
کلیدواژه ها:
نویسندگان
Mohamad Pursamimi
Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Mahdi Ghorbani
Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Mehdi Khosravi
Radiotherapy Center, Shahid Beheshti Hospital, Qom, Iran
Seyed Mohammad Hosseini
Department of Medical Physics and Medical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Ahmad Shakeri
Velenjak, Arabi Street
Sibusiso Mdletshe
Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :