Accuracy of splinted and non-splinted impression techniques for angulated implants in an edentulous mandibular model
سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 1
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JDMT-14-4_003
تاریخ نمایه سازی: 24 دی 1404
چکیده مقاله:
Objective: This in vitro study aimed to compare the accuracy of splinted versus non-splinted open-tray impression techniques for angulated implants in an edentulous mandibular model.Methods: In this in vitro study, three acrylic edentulous mandibular models were used, each containing three implants placed at angulations of ۰°, ۱۵°, and ۲۵°. Five impressions were obtained from each model using either splinted or non-splinted open-tray techniques (n=۵ per technique/angulation, total n=۳۰). The impressions were made using polyvinyl siloxane with either splinted or non-splinted copings. Reference scans obtained from a laboratory scanner served as the gold standard. Three-dimensional (۳D) deviations between test and reference datasets were measured using Geomagic Control X software, and the results were analyzed by two-way ANOVA at the significance level of P<۰.۰۵.Results: The mean ۳D deviations were ۵۷.۹۰ ± ۱۲.۶۵ µm for non-splinted impressions and ۶۱.۸۴ ± ۱۵.۸۴ µm for splinted impressions. The mean deviation was lowest at ۱۵° (۵۶.۳۸ ± ۱۴.۸۳ µm) and highest at ۲۵° (۶۴.۴۴ ± ۱۴.۶۲ µm).No significant difference was observed in the accuracy of different impression techniques (P=۰.۵۳۵). Furthermore, implant angulation did not significantly affect impression accuracy (P=۰.۴۰۱).Conclusions: Within the limitations of this study, the splinted open-tray technique demonstrated comparable accuracy to the non-splinted technique. Implant angulation up to ۲۵° did not significantly affect the precision of splinted and non-splinted open-tray impressions.
کلیدواژه ها:
نویسندگان
Mohammadreza Nakhaei
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
Hamidreza Rajati Haghi
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
Saied Sabzevari
Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
Mohammad Shirdel
Dental Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :