Optimization of Deaerator Operating Pressure in a Dual-Pressure Combined Cycle Power Plant

سال انتشار: 1404
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 100

فایل این مقاله در 5 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ISME33_334

تاریخ نمایه سازی: 2 دی 1404

چکیده مقاله:

Combined cycle power plants (CCPPs) around the world play a significant role in supplying electrical energy. Therefore, optimizing their performance is of great importance for sustainable development. Numerous parameters influence the performance of these types of power plants. In the present study, the effect of deaerator operating pressure under different ambient conditions, including average, maximum, and minimum site temperature, on power output and thermal efficiency of the Heat Recovery Steam Generator (HRSG) is investigated. Ultimately, it is observed that optimizing the deaerator pressure under each ambient condition maximizes the steam turbine's power output.

کلیدواژه ها:

Heat Recovery Steam Generator (HRSG) ، Deaerator ، Combined Cycle Power Plant ، Steam Turbine ، Parametric Study

نویسندگان

Mohammad Davoodi

Basic design expert of HRSG, MAPNA Boiler and Equipment Engineering and Manufacturing Company, Tehran

Ardeshir Mohammadian

Basic design expert of HRSG, MAPNA Boiler and Equipment Engineering and Manufacturing Company, Tehran

Saeid Javan

Basic design expert of HRSG, MAPNA Boiler and Equipment Engineering and Manufacturing Company, Tehran

Moein Farmahini-Farahani

Basic design expert of HRSG, MAPNA Boiler and Equipment Engineering and Manufacturing Company, Tehran

Meisam Marvi

Design manager of HRSG, MAPNA Boiler and Equipment Engineering and Manufacturing Company, Tehran