Characterization of the Radioluminescence Response of Ge-Doped Silica Fibers for ۶ MV Radiotherapy Beam Profile Dosimetry

سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 75

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-22-4_001

تاریخ نمایه سازی: 12 آذر 1404

چکیده مقاله:

Introduction: Accurate radiation dose measurement in both target and non-target tissues is essential in modern external beam radiotherapy. In dosimetry systems, the goal is to deliver the maximum dose to the target volume while ensuring minimal exposure to the surrounding normal cells. Among various medical dosimetry systems like thermoluminescence (TL), optically stimulated luminescence (OSL), and radioluminescence (RL), the RL system offers a real-time monitoring system.Material and Methods: This study aims to characterize the Ge-doped probe in making beam profile measurements using the myDoz® RL/OSL dosimetry system and comparing its accuracy with a CC-۱۳ ion chamber. The RL system utilized a ۳۰-meter PMMA optical fiber with a Ge-doped optical fiber scintillator probe. Beam profiles were measured for ۳ × ۳ and ۱۰ × ۱۰ cm² field sizes at a depth of ۱.۵ cm in solid water, with a source-to-surface distance (SSD) of ۱۰۰ cm, using a ۶ MV photon beam, ۴۰۰ MU/min dose rate, and a total dose of ۳ Gy.Results: The RL readout mechanism enabled instantaneous dose and dose-rate readings. The results showed high consistency and close agreement with the CC-۱۳ ion chamber, with beam profiles displaying uniform central dose, sharp penumbra, and strong symmetry. Larger fields exhibited increased flatness due to photon dispersion. Moreover, the dose distribution out-of-field may still cause low-dose exposure to normal tissues.Conclusion: To sum up, Ge-doped fibers demonstrated excellent real-time, high-resolution performance, making them promising alternatives to traditional dosimeters. Future research should focus on clinical implementation and system optimization for advanced radiotherapy methods.

کلیدواژه ها:

In ، Vivo Dosimetry Radioluminescence Ge ، Doped Silica Fiber Beam Profile Flatness LINAC

نویسندگان

Rajada Khatun

PSO &Head, Medical Physics Division Atomic Energy Centre, ۴ Kazi Nazrul Islam Avenue, Shahbag, Dhaka-۱۰۰۰ Bangladesh Atomic Energy Commission

Md Masud Alam

Department of Physics, Jahangirnagar University, Savar, Dhaka, Bangladesh

Md. Kabir Sikder

Department of Physics, Jahangirnagar University, Savar, Dhaka, Bangladesh

Mir Tahsin Ahmed

Department of Nuclear Engineering, University of Dhaka, Dhaka, Bangladesh

Md. Abul Hasnat

Institute of Nuclear Medical Physics, AERE, Savar, BAEC, Bangladesh

H.T. Zubair

Center for Fiber Networking and Communication, COE for Intelligent Network, Multimedia University, ۶۳۱۰۰ Cyberjaya, Selangor, Malaysia

Shirin Akter

Medical Physics Division, Atomic Energy Centre, Dhaka, Bangladesh

Ashrafun Monika

Medical Physics Division, Atomic Energy Centre, Dhaka, Bangladesh

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Rahman S. Organ risk assessment by TLO to improve treatment ...
  • Zhuang Q, Li J, Li Y, Zhu S, Liu Y, ...
  • Andersen CE. Fiber‐coupled luminescence dosimetry in therapeutic and diagnostic radiology. ...
  • Marckmann CJ, Aznar MC, Andersen CE, Bøtter-Jensen L. Influence of ...
  • Wang H, Rea A, Rudek B, Chen T, McCarthy A, ...
  • نمایش کامل مراجع