Performance of a Tube-bundle Heat Exchanger in a Rectangular-section Right-angle Bend Duct

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 35

فایل این مقاله در 19 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JAFM-19-1_013

تاریخ نمایه سازی: 23 آبان 1404

چکیده مقاله:

Three-dimensional numerical simulations are conducted to elucidate the fundamental differences in hydrodynamics and heat transfer performance between heat exchangers arranged in confined rectangular-section right-angle bend ducts and those in straight ducts, with a specific focus on applications such as gas‑quenching furnaces. The effects of the tube-bundle arrangement and number of tube rows on the pressure drop (Δp) and heat‑transfer rate (Q) are examined under identical inlet conditions. Based on the performance differences, improved correlations are established for pressure drop and heat transfer performance applicable to rectangular bend ducts. The results demonstrate a definitive ordering of pressure drops: Δpss (staggered arrangement, straight duct) > Δpsi (in-line arrangement, straight duct) > Δpbi (in-line arrangement, bend duct) > Δpbs (staggered arrangement, bend duct), and a parallel hierarchy for heat‑transfer rates: Qₛₛ > Qₛᵢ > Qbᵢ > Qbₛ. Although staggered arrangements achieve only modest heat‑transfer gains over in-line arrangements, their marked reduction in pressure drop yields the optimal overall performance evaluation criterion. Both the friction factor fb and Nusselt number Nub of the bend duct increase with the number of tube rows, though their growth attenuates as the tube pitch decreases. These mechanistic insights lead to improved empirical correlations for predicting Δpb and Nub in bend ducts. Validations against simulation data show deviations within ±۵%, effectively overcoming the limitations of straight-duct formulas in complex bend-duct geometries. These correlations provide a solid theoretical basis for optimizing the design and performance of bend-duct heat exchangers in confined spaces.

کلیدواژه ها:

نویسندگان

X. Wang

Hebei Key Laboratory of Low Carbon and High-Efficiency Power Generation Technology, North China Electric Power University, Baoding ۰۷۱۰۰۳, Hebei, China

C. Li

Hebei Key Laboratory of Low Carbon and High-Efficiency Power Generation Technology, North China Electric Power University, Baoding ۰۷۱۰۰۳, Hebei, China

Y. Yan

Hebei Key Laboratory of Low Carbon and High-Efficiency Power Generation Technology, North China Electric Power University, Baoding ۰۷۱۰۰۳, Hebei, China

X. Ye

Hebei Key Laboratory of Low Carbon and High-Efficiency Power Generation Technology, North China Electric Power University, Baoding ۰۷۱۰۰۳, Hebei, China

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :