Research on the Three-dimensional Transient Characteristics of the Hydraulic System during Load Rejection with Combined Regulation of Ball Valve and Guide Vanes in the Entire Hydraulic Passage of the Pumped Storage Power Stations

سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 39

فایل این مقاله در 22 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JAFM-18-9_002

تاریخ نمایه سازی: 30 تیر 1404

چکیده مقاله:

The complex transient flow field in the entire hydraulic system of a large pump turbine under load rejection conditions, involving the simultaneous closing of the ball valve and guide vanes, is comprehensively investigated using the Re-Normalization Group (RNG)k-e model and Fast Fourier Transform (FFT) technique. The predicted pressures at the volute inlet and guide vane outlet show good agreement with the field test data, with corresponding relative errors of ۰.۸۷% and ۰.۳۳%, respectively, between the predicted maximum pressures and those measured in the field. The main frequencies of pressure at the volute inlet are the unit rotating frequency during the initial time stages (۰–۳s), and low-frequency fluctuations in the later stages (۳–۸s and ۸–۱۱s). In contrast, the corresponding frequencies at the guide vane outlet are consistent with the blade frequency. During the ball valve closing process, as the unit rotational speed increases, complex flow separations cause vortices near the middle of the runner to coalesce into two large vortices of similar size. Meanwhile, the cross-sectional area of the vortex rope in the draft tube increases, and its spiral shape becomes increasingly irregular until it breaks apart. Based on the Q criterion, a series of ۳D complex vortices form inside and downstream of the ball valve at the onset of the combined closing stage, intensifying as the guide vanes close. A spiral-shaped vortex rope in the draft tube extends downstream, breaking into smaller vortices after passing through the draft tube elbow, with the location of the fracture moving upstream as the flow rate decreases further.

نویسندگان

X. Li

Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing, ۱۰۰۰۸۳, China

X. Tang

Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing, ۱۰۰۰۸۳, China

Q. Ren

CGGC International LTD., Beijing, ۱۰۰۰۰۰, China

Q. Liu

North China University of Water Resources and Electric Power, Zhengzhou, He’nan, ۴۵۰۰۰۰, China

H. An

Worcester Polytechnic Institute, Worcester, ۰۱۶۰۹, USA

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Avdyushenko, A. Y., Cherny, S. G., Chirkov, D. V., Skorospelov, ...
  • Li, X., Tang, X., Shi, X. Chen, H., & Li, ...
  • Vakil, A., & Firouzabadi, B. (۲۰۰۹). Investigation of valve-closing law ...
  • نمایش کامل مراجع