Performances analysis of Sugar/EPR, Lithium Formate Monohydrate/EPR and Sulfamic acid/EPR dosimetry systems in evaluation of doses delivered during the prostate cancer treatment, using an anthropomorphic phantom

سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 24

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-22-2_008

تاریخ نمایه سازی: 30 تیر 1404

چکیده مقاله:

Introduction: The aim of this work is to test the suitability of the three dosimetry systems: sugar/EPR (Electron Paramagnetic Resonance), lithium formate monohydrate/EPR (LFM/EPR) and sulfamic acid/EPR in the control and assessment of the dose delivered in tumor volume and surrounding organs during radiotherapy treatment of prostate cancer. Thus, the study proposes to compare the doses calculated by the treatment planning system (TPS) with the doses measured by the three dosimetry systems used, in order to verify their ability to evaluate the clinical doses administered. Material and Methods: To perform this work, the various dosimeters studied were placed at the level of the tumor and the surrounding organs in a male anthropomorphic phantom. To simulate radiation therapy for prostate cancer, the phantom used was irradiated by ۶ MV X-rays after careful implementation of a treatment plan for the determination and execution of the prescribed dose, using CT (Computed Tomography) imaging and TPS calculations. Results: The irradiated dosimeters were analyzed by EPR and the determined doses were compared to the doses calculated by the TPS system. The results obtained show that the doses measured by the studied dosimetry systems are similar to calculated doses. The sugar/EPR system appears to be more accurate than the other two dosimetry systems. Conclusion: The three dosimetry systems used show promise for applications as dosimeters in radiotherapy.

کلیدواژه ها:

نویسندگان

Fatna ZAHIRI

Laboratory of Mathematics, Computer Science and Engineering Sciences, Faculty of Science and Technology, Hassan First University, Settat, Morocco

Mohammed MIKOU

Laboratory of Mathematics, Computer Science and Engineering Sciences, Faculty of Science and Technology, Hassan First University, Settat, Morocco

Redouane EL BAYDAOUI

Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences (ISSS), Hassan First University, Settat, Morocco

Kamal Saidi

Laboratory of Sciences and Health Technologies, Higher Institute of Health Sciences (ISSS), Hassan First University, Settat, Morocco. Department of Radiotherapy, Sheikh Khalifa International University Hospital, Casablanca, Morocco

Hanae EL GOUACH

Department of Radiotherapy, Sheikh Khalifa International University Hospital, Casablanca, Morocco

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • ICRU Report ۲۴. Determination of absorbed dose in a patient ...
  • Della Atuwo-Ampoh V, Naab Manson E, Schandorf C, Nii Tagoe ...
  • Gopiraj A, Billimagga RS, Ramasubramanian V. Performance characteristics and commissioning ...
  • نمایش کامل مراجع