Performance of Circular Footing on Expansive Soil Bed Reinforced with Geocells of Chevron Pattern
محل انتشار: ژورنال مهندسی عمران، دوره: 5، شماره: 11
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 68
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_CEJ-5-11_004
تاریخ نمایه سازی: 28 تیر 1404
چکیده مقاله:
Results from laboratory model tests performed on circular footing are presented in this paper to understand the performance of geocell reinforced expansive soil. Naturally occurring expansive soil was used in this study as subsoil. Geocells of chevron pattern fabricated from geotextile made up of polypropylene were used to reinforce the soil bed. The parameters studied in this testing program were the placement depth of the geocell mattress, pocket size of geocell and the height of geocell mattress. Contrary to other researchers; the improvement in the performance of reinforced bed is evaluated at a settlement level equal to the failure settlement of unreinforced soil bed. The performance of reinforced bed is evaluated through two non-dimensional factors viz. bearing capacity improvement factor (If) and settlement reduction factor (PRS%). Test results indicated that with the introduction of geocell as reinforcement, a substantial improvement in bearing capacity and decrease in footing settlement can be achieved. Bearing capacity of reinforced bed increases by more than ۲۰۰% and ۸۱% reduction in footing settlement was achieved by using geocell mattress of optimal dimensions and placing it just below the footing base.Results from laboratory model tests performed on circular footing are presented in this paper to understand the performance of geocell reinforced expansive soil. Naturally occurring expansive soil was used in this study as subsoil. Geocells of chevron pattern fabricated from geotextile made up of polypropylene were used to reinforce the soil bed. The parameters studied in this testing program were the placement depth of the geocell mattress, pocket size of geocell and the height of geocell mattress. Contrary to other researchers; the improvement in the performance of reinforced bed is evaluated at a settlement level equal to the failure settlement of unreinforced soil bed. The performance of reinforced bed is evaluated through two non-dimensional factors viz. bearing capacity improvement factor (If) and settlement reduction factor (PRS%). Test results indicated that with the introduction of geocell as reinforcement, a substantial improvement in bearing capacity and decrease in footing settlement can be achieved. Bearing capacity of reinforced bed increases by more than ۲۰۰% and ۸۱% reduction in footing settlement was achieved by using geocell mattress of optimal dimensions and placing it just below the footing base.
کلیدواژه ها:
Circular Footing Expansive Soil Geocell Mattress Chevron Pattern Bearing Capacity.
نویسندگان
Sanjeev Kumar
Research Scholar, IKG Punjab Technical University, Kapurthala (Punjab),, India
Anil Kumar Sahu
Professor, Department of Civil Engineering, Delhi Technological University, Delhi,, India
Sanjeev Naval
Associate Professor, Department of Civil Engineering, DAV Institute of Engineering & Technology, Jalandhar,, India