SIFCON is a special type of fiber reinforced concrete (FRC) with an unattached fiber matrix that gives the composite matrix important tensile properties and, due to its high fiber content, SIFCON also has distinctive and unique ductility and energy absorption properties. Higher temperature resistance is one of the most important parameters affecting the durability and service life of the material. In this research, the compression strength and elastic modulus of Slurry Infiltrated Fiber Concrete (SIFCON) were tested both before and after exposure to high temperatures. Two fire exposure durations of ۲ and ۳ hours are examined. In addition to room temperatures, three temperature ranges of ۴۰۰ ° C, ۶۰۰ ° C and ۹۰۰ ° C have been introduced. The results of the experiment showed that the compressive strength and elastic modulus decreased after exposure to high temperatures. The drastically reduction of compressive strength took place with increasing temperature above ۶۰۰ °C. While, the reduction in elastic modulus values is more significant than the decrease in compressive strength at the same fire flame temperatures. The residual compressive strength and elastic modulus at ۹۰۰ °C were in the range of (۵۲.۱% to ۵۹.۶%) and (۳۰.۶% to ۳۴.۱%) respectively.SIFCON is a special type of fiber reinforced concrete (FRC) with an unattached fiber matrix that gives the composite matrix important tensile properties and, due to its high fiber content, SIFCON also has distinctive and unique ductility and energy absorption properties. Higher temperature resistance is one of the most important parameters affecting the durability and service life of the material. In this research, the compression strength and elastic modulus of Slurry Infiltrated Fiber Concrete (SIFCON) were tested both before and after exposure to high temperatures. Two fire exposure durations of ۲ and ۳ hours are examined. In addition to room temperatures, three temperature ranges of ۴۰۰ ° C, ۶۰۰ ° C and ۹۰۰ ° C have been introduced. The results of the experiment showed that the compressive strength and elastic modulus decreased after exposure to high temperatures. The drastically reduction of compressive strength took place with increasing temperature above ۶۰۰ °C. While, the reduction in elastic modulus values is more significant than the decrease in compressive strength at the same fire flame temperatures. The residual compressive strength and elastic modulus at ۹۰۰ °C were in the range of (۵۲.۱% to ۵۹.۶%) and (۳۰.۶% to ۳۴.۱%) respectively.
کلیدواژه ها:
SIFCON Steel Fiber Fire Elastic Modulus Compressive Strength.
نویسندگان
Ali Mudhafar Hashim
Department of Civil Engineering, College of Engineering, University of Babylon, Babylon,, Iraq
Mohammed Mansour Kadhum
Department of Civil Engineering, College of Engineering, University of Babylon, Babylon,, Iraq