چکیده مقاله:

The objective of using materials is to fully utilize the properties of these materials in order to obtain the best performance of the structure. The merits of material are based on many factors like, workability, structural strength, durability and low cost. Ferrocement is an excellent construction system. This paper studies the behavior of ferrocement circular slabs under impact load. The experimental program include testing four sime fixed supported ferrocement circular slabs of ۸۰۰mm diameter and ۵۰mm thickness. The Influence of the use of styropor voids was investigated in different ratios (۲۴% and ۴۸%) and a number of wire mesh layers four and six layers. Impact load test results revealed that increasing number of wire mesh from ۴ to ۶ led to an increase in the impact energy for first crack by (۴۱.۹۹۱% ,۳۷.۶۲%) respectively when using voids ratio by (۲۴% and ۴۸%) respectively and impact energy for full perforation by (۲۱.۷% and ۹.۹۴%) respectively when using voids ratio by (۲۴% and ۴۸%) respectively. Ferrocement circular slabs are used in construction fields such as roofs, tanks, manholes, etc.The objective of using materials is to fully utilize the properties of these materials in order to obtain the best performance of the structure. The merits of material are based on many factors like, workability, structural strength, durability and low cost. Ferrocement is an excellent construction system. This paper studies the behavior of ferrocement circular slabs under impact load. The experimental program include testing four sime fixed supported ferrocement circular slabs of ۸۰۰mm diameter and ۵۰mm thickness. The Influence of the use of styropor voids was investigated in different ratios (۲۴% and ۴۸%) and a number of wire mesh layers four and six layers. Impact load test results revealed that increasing number of wire mesh from ۴ to ۶ led to an increase in the impact energy for first crack by (۴۱.۹۹۱% ,۳۷.۶۲%) respectively when using voids ratio by (۲۴% and ۴۸%) respectively and impact energy for full perforation by (۲۱.۷% and ۹.۹۴%) respectively when using voids ratio by (۲۴% and ۴۸%) respectively. Ferrocement circular slabs are used in construction fields such as roofs, tanks, manholes, etc.

کلیدواژه ها:

Ferrocement Circular Slabs Impact Load Voided slabs Composite Panel.

نویسندگان

Muyasser M. Jomaah

Civil Engineering Department, College of Engineering, University of Tikrit, Iraq., Iraq

Muna Zead Baraa

Civil Engineering Department, College of Engineering, University of Tikrit, Iraq., Iraq