Effect of Earthquake loads on School Buildings in the Kingdom of Saudi Arabia

سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 29

فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_CEJ-5-1_012

تاریخ نمایه سازی: 28 تیر 1404

چکیده مقاله:

Background: The designing of the reinforced concrete building for the reduction of the seismic load has significantly gained popularity. Most of the buildings in Saudi Arabia are designed for the gravity load, based on its seismicity level. Objective: The study evaluates the effects of the earthquake load on the RC school building located in Saudi Arabia. Method: An equivalent static analysis technique used to apply the seismic analysis and design method according to Saudi Building Code SBC۳۰۱ (۲۰۰۷). This design code is used to redesign the chosen school building. The SAP ۲۰۰۰ structural analysis software was used to analyses and study the structure behaviour due to the seismic load. Results: The results of the study provide that the RC school building design in Saudi Arabia is inadequate, and unsafe for the earth quakes. Conclusion: One of the important conclusions in this study is that the designer of the school building in Saudi Arabia should take into consideration the earthquake loads. It also emphasizes on the development of the adequate framework for the implementation of the safe designing of the buildings inclusive of earthquake safety measures.Background: The designing of the reinforced concrete building for the reduction of the seismic load has significantly gained popularity. Most of the buildings in Saudi Arabia are designed for the gravity load, based on its seismicity level. Objective: The study evaluates the effects of the earthquake load on the RC school building located in Saudi Arabia. Method: An equivalent static analysis technique used to apply the seismic analysis and design method according to Saudi Building Code SBC۳۰۱ (۲۰۰۷). This design code is used to redesign the chosen school building. The SAP ۲۰۰۰ structural analysis software was used to analyses and study the structure behaviour due to the seismic load. Results: The results of the study provide that the RC school building design in Saudi Arabia is inadequate, and unsafe for the earth quakes. Conclusion: One of the important conclusions in this study is that the designer of the school building in Saudi Arabia should take into consideration the earthquake loads. It also emphasizes on the development of the adequate framework for the implementation of the safe designing of the buildings inclusive of earthquake safety measures.

کلیدواژه ها:

Effect Saudi Building Code (SBC۳۰۱-۲۰۰۷) School Building Seismic Saudi Arabia.

نویسندگان

Yasser Alashker

Associate Professor, Department of Structural Engineering, Zagazig University, Zagazig,۴۴۵۱۹, Egypt. Assistant Professor, Department of Civil Engineering, King Khalid University, Abha,۶۱۴۲۱, KSA., Egypt

Khalid Elhady

Assistant Professor, Department of Civil Engineering, King Khalid University, Abha,۶۱۴۲۱, KSA., Saudi Arabia

Mohammed Ismaeil

Assistant Professor, Department of Civil Engineering, King Khalid University, Abha,۶۱۴۲۱, KSA, on leave from Sudan University for Science and Technology, Khartoum, ۷۹۳۷۱, Sudan., Sudan