Determination of Chemical Exchange Rate in Chemical Exchange Saturation Transfer (CEST) Phenomenon in Magnetic Resonance Imaging through Analytical Solution of Bloch-McConnell Equations

سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 146

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_TMCH-4-4_004

تاریخ نمایه سازی: 23 تیر 1404

چکیده مقاله:

Magnetic Resonance Imaging (MRI), by enabling the non-invasive measurement of certain physiological markers, facilitates the study and tracking of molecular states, ultimately leading to the early diagnosis of diseases. Chemical Exchange Saturation Transfer (CEST) serves as a novel contrast mechanism in MRI for molecular studies. This contrast depends on multiple parameters, including relaxation times, the chemical exchange rate between water molecules and the contrast agent, the concentration of the contrast agent, and the properties of the applied radiofrequency (RF) pulse. The chemical exchange rate is a crucial parameter, as it correlates with various clinical indicators such as pH, temperature, and metabolite concentration. However, its direct measurement remains challenging. In this study, a method for determining this rate using RF pulse width is proposed. First, the CEST effect is expressed in an analytical relationship, demonstrating that this contrast reaches its maximum at a specific RF pulse width. This analytical expression distinguishes the CEST effect from the magnetic transfer effects caused by macromolecules in biological tissues, which act as confounding factors. Assuming a known contrast concentration, the chemical exchange rate can be determined through an analytical relationship based on the RF pulse width that maximizes the CEST effect. The validity of this analytical relationship is confirmed by comparison with widely accepted definitions of the CEST effect. Furthermore, by applying a Taylor series expansion to the analytical expression, relevant formulas from reputable publications are derived. The study employs validated data from a three-pool structure, which is consistent with biological tissue models referenced in authoritative sources. It is recommended that the findings of this study be practically implemented on MRI scanners.

کلیدواژه ها:

نویسندگان

M. R.

Assistant Professor, Department of Biomedical Engineering, Hamedan University of Technology, Hamedan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :