A Method to Justify Process Control Systems in Mineral Processing Applications
سال انتشار: 1392
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 7
فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJCCE-32-4_011
تاریخ نمایه سازی: 17 خرداد 1404
چکیده مقاله:
The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of ۰.۳۸ to ۰.۰۶. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of ۱,۰۰۰,۰۰۰ was found to be ۲ years.The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of ۰.۳۸ to ۰.۰۶. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of ۱,۰۰۰,۰۰۰ was found to be ۲ years.
کلیدواژه ها:
نویسندگان
Gholamabbas Parsapour
Mining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box ۷۶۱۷۵-۱۳۳ Kerman, I.R. IRAN
Mostafa Maleki
Mining Engineering Group, ValiAsr University of Rafsanjan, P.O. Box ۵۱۸ Rafsanjan, I.R. IRAN
Samad Banisi
Mining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box ۷۶۱۷۵-۱۳۳ Kerman, I.R. IRAN
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :