چکیده مقاله:

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-۴-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -۵۵.۰ ± ۱.۰ mV/decade and a linear range of  for perchlorate. The limit of detection is . It has a fast response time <۱۵s and can be used for more than three months. The selective coefficients of Perchlorate-selective electrode were determined by the Fixed Interference Method (FIM) and Fixed Primary ion Method (FPM), and could be used in the pH range ۴.۰-۹.۰. It was employed as an indicator electrode for direct determination of perchlorate in real samples.

نویسندگان

Mohammad Mazloum-Ardakani

Department of Chemistry, Faculty of Science, Yazd University, P.O. Box ۸۹۱۹۵-۷۴ Yazd, I.R. IRAN

Roya Mazidi

Department of Chemistry, Payam Noor University, Ardakan Branch, Ardakan, I.R. IRAN

Mohammad Hossein Mashhadizadeh

Department of Chemistry, Tarbiat Moalem University, Tehran, I.R. IRAN

Hossein Naeimi

Faculty of Chemistry, University of Kashan, Kashan, I.R. IRAN

Kobra Rabiei

Faculty of Chemistry, University of Kashan, Kashan, I.R. IRAN

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Urbansky E.T., Brown S.K., Magnuson M.L., Kelty C.A., Perchlorate Level ...
  • Urbansky E.T., Perchlorate as an Environmental Contaminant, Environ. Sci. Pollut. ...
  • Motzer W.E., Perchlorate: Problems, Detection, and Solutions, Environ. Forencics, ۲, ...
  • Rodriguez A.F., Davidson H.G., Villadiego M.S., Fernandez A.M., Lacave I.M., ...
  • Wolff J., Perchlorate and the Thyroid Gland, Pharmacological Reviews, ۵۰, ...
  • NationalAcademyof Sciences, "Health implications of perchlorate ingestion", Prepublication copy, National ...
  • USEPA, "US EPA Headquarters Press Release: EPA Sets References Dose ...
  • Atwood D.A., HarveyM.J., Group ۱۳ Compounds Incorporating Salen Ligands, Chem. ...
  • Johnson C.P., Atwood J.L., Steed J.W., Bauer C.B., RogersR. D., ...
  • Alizadeh N., Ershad S., Naeimi H., Sharghi H., Shamsipur M., ...
  • Bühlman P., Prestsch E., Bakker E., Carrier-Based Ion-Selective Electrodes and ...
  • Bakker E., Bühlman P., Prestch E., Carrier-Based Ion-Selective Electrodes and ...
  • Shamsipur M., Sadeghi S., Naeimi H., Sharghi H., Iodide Ion-Selective ...
  • Mazloum Ardakani M., Mashhadizadeh M. H., Karimi M. A., Azimi ...
  • Hassan S.S.M., Elsaied M.M., A New Liquid-Membrane Electrode for Selective ...
  • Bäck S., Selectivity Studies on Anion-Selective Membrane Electrodes, Anal. Chem., ...
  • Kataoka M., Kambara T., A Liquid Membrane Type Perchlorate Ion-Selective ...
  • Mazloum Ardakani M., Salavati M., Dastanpoor A., A Highly Selective ...
  • Mazloum Ardakani M., Salavati M., Jamshidpoor M., Selective Nitrate Poly(Vinylchloride) ...
  • Mazloum Ardakani M., Salavati M., Sadeghi A., Novel Selective thiocyanate ...
  • Amini M.K., Mazloum Ardakani M., Ensafi A.A., Lead Selective membrane ...
  • Kamata S., Bhal A., Fakunaga Y., Marata A., Copper(II)-Selective Electrode ...
  • Amemiya S., Bühlmann P., Pretsch E., Cationic or Anionic Sites ...
  • Schaller U., Bakker E., Pretsch E.,Carrirer Mechanism of Acidic Ionophores ...
  • Mazloum Ardakani M., Jalayer M., Naeimi H., Zare H.R., Moradi ...
  • Ammann D., Pretsch E., Simon W., Lindner E., Bezegh A., ...
  • Mazloum-Ardakani M., Iranpoor F., Karimi M. A., Salavati-Niasari M.,A New ...
  • Huser M., Gehrig P.M., Morf W.E., Simon W., Lindner C., ...
  • Wegmann D., Weiss H., Ammann D., Morf W.E., Pretsch E., ...
  • Buck R. P., Ion Selective Electrodes, Potentiometry, and Potentiometric Titrations, ...
  • Buck R. P., Lindner E., Recommendation for Nomenclature of Ion-Sensitive ...
  • Danuert S., Wallace S., FloridaA., Bachas L. G., Anion-Selective Electrodes ...
  • Sanchez-Pedreno C., Ortuno J. A., Hernandez J., Perchlorate-Selective Polymeric Membrane ...
  • Shamsipur M., Soleymanpour A., Akhond M., Sharghi H., Hasaninejad A. ...
  • Olmos R.P., Rios A., Martin M.P., Lapa R.A.S., Lima J. ...
  • Tatyana A. B., Thomas C. H., Long-Lived Solid State Perchlorate ...
  • Sabater J.L., Seguí M.J., Lloris J.M., Martínez-Máñez R., Pardo T., ...
  • Rezaei B., Meghdadi S., Bagherpour S., Perchlorate-Selective Polymeric Membrane Electrode ...
  • Soleymanpour A., Hamidi asl E., Nabavizadeh S. M., Perchlorate Selective ...
  • Arvand M., Pourhabib A., Shemshadi R., Giahi M., The Potentiometric ...
  • نمایش کامل مراجع