A Microfluidic Device to Apply Uniform Shear Stress to the Cells

سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 100

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_PRJMS-23-3_001

تاریخ نمایه سازی: 28 اسفند 1403

چکیده مقاله:

The invention of microfluidic devices has led to a dramatic change in engineering, medicine, and biomedicine. Microfluidic devices provide the conditions for cell culture in real body dimensions. In the present study, a microfluidic chip was fabricated that is capable of keeping cells alive under dynamic flow conditions. This microchip consists of a microchannel in which cells are cultured. Different amounts of shear stress are exerted to the cells by passing culture media. The results of the flow field simulation show that in the flow rate of ۱ to ۱۰۰ microliters per minute, the shear stress distribution is uniform. In this range of flow rate, shear stress varies from ۰.۰۰۵۴۳۴ to ۰.۵۴۳۲dyn/cm۲, which is within the allowable shear stress for cells. Large shear stresses, such as a flow rate of ۱۰۰۰ microliters per minute, cause the cell wall to rupture, and eventually disintegration. The experimental results confirm that the growth and proliferation of cells vary for different amounts of growth factor as a chemical factor. The cells filled the microchannel for a growth factor of ۱۵% on the fifth day of culture, while without growth factor, the microchannel was filled on the seventh day. The results indicate that this microchip can maintain cells alive for more than a week. Also, by adjusting the flow, different amounts of shear stress can be applied to the cells. Therefore, this microchip can perform various cellular tests to investigate the effect of shear stress on the cells.

نویسندگان

هاجر مقدس

Department of Mechanical Engineering, Faculty of Gas and Petroleum, Yasouj University, Gachsaran, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Santana HS, Silva JL, Aghel B, Ortega-Casanova J. Review on ...
  • Cui P, Wang S. Application of microfluidic chip technology in ...
  • Jang KJ, Cho HS, Kang DH, Bae WG, Kwon TH, ...
  • Yao J, Zhu G, Zhao T, Takei M. Microfluidic device ...
  • Giridharan V, Yun Y, Hajdu P, Conforti L, Collins B, ...
  • Mina SG, Wang W, Cao Q, Huang P, Murray BT, ...
  • Feng Sh, Mao S, Zhang Q, Li W, Lin JM. ...
  • Kim TH, Lee JM, Ahrberg CD, Chung BG. Development of ...
  • Ma C, Geng B, Zhang X, Li R, Yang X, ...
  • Zhang J, Wei X, Zeng R, Xu F, Li X. ...
  • Chikamori M, Kimura H, Inagi R, Zhou J, Nangaku M, ...
  • Schneider I, Baumgartner W, Gröninger O, Stark WJ, Märsmann S, ...
  • Chen ZZ, Yuan WM, Xiang Ch, Zeng DP, Liu B, ...
  • Zhang B, Xie F, Shao Sh, Aziz A, Li W, ...
  • Moghadas H, Saidi MS, Kashaninejad N, Nguyen NT. Challenge in ...
  • Delon LC, Guo Z, Kashani MN, Yang CT, Prestidge C, ...
  • Lin JY, Lo KY, Sun YS. A microfluidics-based wound-healing assay ...
  • Yan Z, Su G, Gao W, He J, Shen Y, ...
  • Moshksayan K, Kashaninejad N, Warkiani ME, Lock JG, Moghadas H, ...
  • Chao PG, Tang Z, Angelini E, West AC, Costa KD, ...
  • Bao X, Li Z, Liu H, Feng K, Yin F, ...
  • Angelozzi M, Penolazzi L, Mazzitelli S, Lambertini E, Lolli A, ...
  • Kowsari-Esfahan R, Jahanbakhsh A, Saidi MS, Bonakdar Sh. A microfabricated ...
  • Kim M, Erickson IE, Choudhury M, Pleshko N, Mauck RL. ...
  • Terraciano V, Hwang N, Moroni L, Park HB, Zhang Z, ...
  • Bonzani IC, Campbell JJ, Knight MM, Williams A, Lee DA, ...
  • McBeath R, Pirone DM, Nelson CM, Bhadriraju K, Chen CS. ...
  • Wang H, Riha GM, Yan S, Li M, Chai H, ...
  • Sun J, Luo Q, Liu L, Song G. Low-level shear ...
  • Yue D, Zhang M, Lu J, Zhou J, Bai Y, ...
  • Huang S, Chen CS, Ingber DE. Control of cyclin D۱, ...
  • Young EW, Wheeler AR, Simmons CA. Matrix-dependent adhesion of vascular ...
  • Liu L, Jiang H, Zhao W, Meng Y, Li J, ...
  • Li Z, Kupcsik L, Yao SJ, Alini M, Stoddart MJ. ...
  • Ferrell N, Desai RR, Fleischman AJ, Roy S, Humes HD, ...
  • Chen H, Yu Z, Bai S, Lu H, Xu D, ...
  • Huh D, Hamilton GA, Ingber DE. From ۳D cell culture ...
  • Raimondi MT, Boschetti FE, Falcone L, Fiore GB, Remuzzi A, ...
  • Jang KJ, Suh KY. A multi-layer microfluidic device for efficient ...
  • Oo ZY, Deng R, Hu M, Ni M, Kandasamy K, ...
  • Ferrell N, Ricci KB, Groszek J, Marmerstein JT, Fissell WH. ...
  • Huh D, Torisawa YS, Hamilton GA, Kim HJ, Ingber DE. ...
  • Jang KJ, Mehr AP, Hamilton GA, McPartlin LA, Chung S, ...
  • نمایش کامل مراجع