Designing a Rapid Screening Method for Detection of Four Common Beta Globin Gene Mutations in Iranian Population by High-Resolution Melting Analysis
محل انتشار: مجله تحقیقات پاتوبیولوژی، دوره: 21، شماره: 2
سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 106
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_PRJMS-21-2_006
تاریخ نمایه سازی: 28 اسفند 1403
چکیده مقاله:
Aims: Beta-thalassemia is a blood and genetic disorder. Prevalence of beta-thalassemia trait is high in Iranian population. Therefore, for detection of carriers’ status in premarital screening we need to establish reliable and rapid scanning method. The aim of this study is development a rapid method to detect four common beta globin gene mutations in Iranian population by HRM (High-Resolution Melting Analysis.
Materials and Methods: In this experimental study, eight samples of beta-thalassemic carriers and illness with IVSI-۱۱۰ (G>A), IVSII-I (G>A), IVSI-۵ (G>C) and CD۳۶/۳۷ (-T) genotypes in Homozygote and heterozygote conditions and one control sample (healthy person) were selected. After blood collection, DNA extraction was performed using salting out method. To ensure, the samples were run binary, and two control samples without DNA were used. Primers were designed with Gene Runner ۶.۰.۲۸, Primer Express v ۳.۰.۱ ۳/۱) and Primer۳ v. ۰.۴.۰ and HRM method was used to determine the above mutations.
Findings: The best concentration of DNA was obtained at ۵ng/μl. In the difference plot step, the differences between the curves were clearly observed in heterozygous, normal and homozygous conditions. Unexpectedly, in the mutation IVSII-IG>A in the melting curve was seen two peaks in the samples; it was due to the presence of a polymorphism near the desired mutation.
Conclusion: The HRM method is capable of detecting the four common beta globin gene mutations, and, it can differentiate between heterozygote and homozygous in a single mutation. This method is high throughput, which can analyze ۹۶ samples of DNA in ۲hours.
کلیدواژه ها:
نویسندگان
محمد حمید
Molecular Medicine Department, Biotechnology Research Center, Pasteur Institute of Iran, Tehran, Iran
سمیه مروتی شریف آباد
Molecular Medicine Department, Biotechnology Research Center, Pasteur Institute of Iran, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :