Comparison of Methods of µ-Map Generation: MR-Based Method in PET/MR Imaging Versus Pseudo-CT Method in Radiotherapy Dose Planning
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 21، شماره: 6
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 83
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-21-6_002
تاریخ نمایه سازی: 26 اسفند 1403
چکیده مقاله:
Introduction: Attenuation correction is essential for accurate PET imaging and radiotherapy (RT) dose planning. However, PET/MR systems face a significant challenge due to the lack of direct attenuation data from MR images, unlike PET/CT where CT provides inherent attenuation information. Similarly, the increasing use of MRI in RT planning necessitates pseudo-CT methods for accurate dose calculation. This study compares MR-based µ-map generation for PET/MR and pseudo-CT methods for RT planning, addressing their challenges and limitations to improve treatment accuracy and patient care. Material and Methods: The study involved patient selection, image processing, and generation of MR-based attenuation maps (µ-maps) for PET attenuation correction and pseudo-CTs for RT dose planning using advanced computational software. Results: MR-based µ-maps, potentially useful for PET attenuation correction, and pseudo CTs, potentially applicable in radiotherapy planning, were successfully generated. Head images showed MR-based µ-maps overestimating bone for two patients (deviations of ۴.۰% and ۴.۲%). Both MR-based and CT µ-maps exhibited dynamic and continuous µ-values for head bone. In the pelvis, pseudo-CT underestimated bone volume in five patients (deviations of ۱۸.۷%, ۲۱.۳%, ۹.۶%, ۱۴%, and ۱۰%). Pseudo-CT's bone µ-values lacked continuity compared to CT µ-maps. Pelvis studies revealed more dynamic and broader µ-value range for muscle in CT µ-maps than pseudo-CT and MRI µ-map. Conclusion: These findings suggest the need for careful consideration and validation of attenuation correction methods, especially in regions with complex anatomical structures, to ensure accurate treatment delivery and enhance patient care in the context of PET/MR and radiotherapy.
کلیدواژه ها:
Magnetic Resonance Imaging (MRI) Computed Tomography (CT) Positron ، Emission tomography (PET) Radiotherapy
نویسندگان
Isaac Kwesi Acquah
University of Education, Winneba, Ghana
Stephen Inkoom
University of Ghana, School of Nuclear and Allied Health Science, Ghana
Francis Hasford
Ghana Atomic Energy Commission, Ghana
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :