A risk-based approach to reduction of warm air infiltration for energy efficiency optimization in a cold storage system-a case study of a fruit packaging plant
سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 25
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_RIEJ-14-2_002
تاریخ نمایه سازی: 7 بهمن 1403
چکیده مقاله:
Warm air infiltration is a hidden phenomenon that can go unnoticed for weeks, months, or even years in cold storage envelopes. It is a common source of energy wastage that can be explored to achieve significant energy and cost savings. This research assesses warm air infiltration into fruit cold storages using a case study approach for an international fruit exporter based in Kenya, covering baseline study, root cause analysis, and developing a risk-based mitigation strategy to minimize the infiltration rates. Thermal graphic measurements, electricity bills, and on-site observation of the operation patterns provided source data. An Ishikawa diagram and a risk-based Failure Mode and Effect Analysis (FMEA) were used to identify and prioritize root causes, respectively, and a modified decision tree was then utilized to structure the mitigation strategy. The study established a lack of awareness of cold storage operations, irregular and untimed maintenance of components, broken door seals, and inconsistency in the frequency of cold storage door openings as the critical root causes for the warm air-infiltration challenge. It was further revealed that cold storage facilities need to take advantage of the available sensory and operational data to introduce maintenance management systems, temperature-airflow monitoring systems, and environmental control devices to complement the functionality of cold storage components. To operate fruit cold storages optimally and efficiently, facilities management must comprehensively understand the sources of temperature variations and adopt mitigation strategies that minimize warm air infiltration. There is no one-size-fits-all approach to reducing warm air infiltration; thus, both systemic and behavioral approaches must be adopted and integrated into cold storage operations.
کلیدواژه ها:
Warm Air Infiltration ، Energy Efficiency Optimization ، Root cause analysis ، Failure Identification and Prioritization ، Mitigation Strategy
نویسندگان
Peter Kibagendi Mokaya
Dedan Kimathi University of Technology, Nyeri, Kenya.
James Wakiru
Dedan Kimathi University of Technology, Nyeri, Kenya.
Josephat Tanui
Dedan Kimathi University of Technology, Nyeri, Kenya.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :