Investigating the Impacts of Climate-Adaptive Building Shells’ Performance on the Indoor Environment Parameters in Kermanshah
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 256
فایل این مقاله در 13 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JREE-11-4_005
تاریخ نمایه سازی: 16 مهر 1403
چکیده مقاله:
Climate-adaptive building shells (CABS) are designed to dynamically respond to environmental parameters, unlike the static facades of traditional buildings, which cannot adjust to external conditions. Traditional building facades often fail to adapt to varying climatic conditions, negatively affecting thermal comfort, visual comfort, and energy efficiency. This limitation is particularly noticeable in office environments, where the quality of the internal environment significantly impacts both staff efficiency and user satisfaction, making it crucial to maintain optimal conditions. This paper aims to (I) explain the reasons for selecting CABS to enhance the performance of building facades and (II) design and present a new example of such a façade. To achieve this, a CABS was designed and evaluated on the facade of an office building in Kermanshah using Rhino-Grasshopper software. The performance of this facade was assessed based on its ability to maintain thermal comfort, provide visual comfort, prevent glare, and offer adequate lighting for office use. Simulation data analyzed using Grasshopper software revealed that implementing CABS in rooms with direct light exposure adjusted the radiant temperature within the comfort zone ۷۳% of the time, representing a ۳۵.۳% improvement over conditions without CABS. These adaptive shells minimize solar heat absorption during peak heat hours, balance internal temperature fluctuations, and, depending on the room's orientation, reduce solar ray intensity, light glare, and the number of dazzling light hours per year. CABS convert sunlight into Useful Daylight Illuminance (UDI) suitable for office environments. Consequently, the use of CABS led to a ۷۹.۵% increase in useful light levels and improved UDI quality and efficiency compared to non-CABS situations.
کلیدواژه ها:
نویسندگان
Arian Amini Pour
Department of Architecture Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran.
Allahbakhsh Kavoosi
Department of Architecture Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :