Impact of Electronic Collimation on Reducing Unnecessary Patient Dose in Digital Radiography
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 14، شماره: 5
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 213
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-14-5_004
تاریخ نمایه سازی: 16 مهر 1403
چکیده مقاله:
Background: In radiology, optimizing radiation protection is crucial, and field collimation plays a critical role in minimizing patient dose. As technology has evolved, electronic collimation has become the preferred method due to its effectiveness in digital imaging systems, replacing traditional film-screen systems.Objective: The current study aimed to investigate the prevalence of cropping in digital radiography and its potential impact on patient radiation dose because of improper collimation practices.Material and Methods: This retrospective analysis was conducted on digital X-ray machine images. Quality control tests were performed to ensure equipment accuracy, and image cropping was then measured by analyzing archived images. Finally, the cropped image fraction and associated unnecessary radiation doses were calculated.Results: Quality control tests confirmed that all imaging equipment was functioned within acceptable alignment and angle tolerances. The analysis of ۹۱۱ images revealed a high prevalence of cropping (۸۲%), with significant variation across different projections. Lateral knee images exhibited the highest cropping rate (۹۶.۲%), while abdominal images had the lowest (۳۶.۱%). Conclusion: Electronic image cropping can lead radiologic technologists to inaccurately define the primary radiation field, affecting image quality and potentially increasing patient radiation exposure. Based on the obtained results, proper collimation can reduce the average Dose Area Product (DAP) by ۲۹.۰۱%. This approach not only enhances patient safety but also minimizes unnecessary radiation exposure and potentially reduces healthcare costs.
کلیدواژه ها:
نویسندگان
Amir Mohammad Esmaeilian
Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
Saeedeh Aliakbari
Department of Radiology, School of Allied Medical Sciences, Semnan University of Medical Sciences, Semnan, Iran
Payman Hejazi
Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
Majid Jadidi
Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :