چکیده مقاله:
In Indonesia, one of the most common forms of connection is the Bolted Flange Plate (BFP) moment connection. Nevertheless, their current setups do not satisfy the strict requirements outlined in AISC ۳۵۸-۲۲. Therefore, this study uses advanced sub-assemblage numerical modeling simulations using ANSYS software to propose a novel way to integrate a half WF extended end-plate connection and trapezoidal haunch in order to fortify BFP moment connections, which does not meet the requirement required by AISC ۳۵۸-۲۲. Methodologically, the research entails comprehensive modeling and analysis of the proposed retrofit scheme. Six distinct connection models were scrutinized: the BFP-UR representing the existing connection extracted from a structure in Surabaya; the BFP-R۴E and BFP-R۴ES models, embodying connection retrofits with a half WF extended end-plate; and the BFP-RTR and BFP-RSTR models, embodying connection retrofits with a trapezoidal haunch. Additionally, the BFP-RTRE model integrates both an extended end plate and a trapezoidal haunch in the retrofit scheme. The analytical findings unveil that the proposed strengthening paradigm manifests heightened and superior rotational moment characteristics relative to the pre-reinforcement configuration, albeit encountering stiffness degradation attributable to buckling effects on the main beam. Notably, the analysis indicates that degradation ensues when rotational displacement exceeds ۴%, with only the BFP-RTR and BFP-RSTR models exhibiting degradation at a ۳% rotation threshold. Crucially, the connections demonstrate the capability to withstand ۸۰% of the beam’s plastic moment under a ۴% rotational displacement, thereby aligning with the stringent requisites delineated in AISC ۳۴۱-۲۲. Doi: ۱۰.۲۸۹۹۱/CEJ-۲۰۲۴-۰۱۰-۰۸-۰۳ Full Text: PDF
کلیدواژه ها:
Retrofitting of Moment Connections ، Bolted Flange Plate ، Prequalified Connections ، Finite Element Method ، Connection Capacity.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :