Application of Electrocoagulation for the Removal of Color from Institutional Wastewater: Analysis with Response Surface Methodology Service Unavailable
محل انتشار: فصلنامه روشهای تصفیه محیط، دوره: 9، شماره: 2
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 185
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JETT-9-2_011
تاریخ نمایه سازی: 22 مرداد 1403
چکیده مقاله:
The removal percentage of color from institutional wastewater was studied using an electrocoagulation process with different electrode combination at the anode and cathode. This was done by considering operational parameters such as pH at (۳, ۶ and ۹), current at (۰.۰۳A, ۰.۰۶A and ۰.۰۹A) and reaction time at (۲۰, ۴۰ and ۶۰ minutes). When electrode combined in the form of Al-Al (anode-Cathode/Cathode-Anode) and Fe-Fe (anode-Cathode/Cathode-Anode) the percentage removal of color was up to ۹۵.۵۰% and ۹۷.۲۴% respectively. On the other hand around ۹۸.۰۳% and ۹۱.۹۵% of color was removed when Al-Fe (Anode-Cathode) and Fe-Al (Anode-Cathode) combined at pH ۹ and ۶۰ minutes of reaction time respectively. Central composite design from response surface methodology was used up to analysis the statistical and mathematical data based on experimental results such as the model was significant for all electrode combinations. Similarly a quadratic model was used for further study of operational effects on the removal (%) of color from institutional wastewater. The value of coefficient of the determination (R۲) also indicated the model was a good fit as well as optimization was done by Response Surface Methodology.The removal percentage of color from institutional wastewater was studied using an electrocoagulation process with different electrode combination at the anode and cathode. This was done by considering operational parameters such as pH at (۳, ۶ and ۹), current at (۰.۰۳A, ۰.۰۶A and ۰.۰۹A) and reaction time at (۲۰, ۴۰ and ۶۰ minutes). When electrode combined in the form of Al-Al (anode-Cathode/Cathode-Anode) and Fe-Fe (anode-Cathode/Cathode-Anode) the percentage removal of color was up to ۹۵.۵۰% and ۹۷.۲۴% respectively. On the other hand around ۹۸.۰۳% and ۹۱.۹۵% of color was removed when Al-Fe (Anode-Cathode) and Fe-Al (Anode-Cathode) combined at pH ۹ and ۶۰ minutes of reaction time respectively. Central composite design from response surface methodology was used up to analysis the statistical and mathematical data based on experimental results such as the model was significant for all electrode combinations. Similarly a quadratic model was used for further study of operational effects on the removal (%) of color from institutional wastewater. The value of coefficient of the determination (R۲) also indicated the model was a good fit as well as optimization was done by Response Surface Methodology.
کلیدواژه ها:
نویسندگان
Million Ebba
Department of Water Supply and Environmental Engineering, Faculty of civil and Environmental Engineering, Jimma University, Institute of technology
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :