Evaluation of Perkin Elmer Amorphous Silicon Electronic Portal Imaging Device for Small Photon Field Dosimetry
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 14، شماره: 4
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 63
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-14-4_003
تاریخ نمایه سازی: 14 مرداد 1403
چکیده مقاله:
Background: Electronic portal imaging devices (EPIDs) are applied to measure the dose and verify patients’ position.Objective: The present study aims to evaluate the performance of EPID for measuring dosimetric parameters in small photon fields.Material and Methods: In this experimental study, the output factors and beam profiles were obtained using the amorphous silicon (a-Si) EPID for square field sizes ranging from ۱×۱ to ۱۰×۱۰ cm۲ at energies ۶ and ۱۸ mega-voltage (MV). For comparison, the dosimetric parameters were measured with the pinpoint, diode, and Semiflex dosimeters. Additionally, the Monaco treatment planning system was selected to calculate the output factors and beam profiles.Results: There was a significant difference between the output factors measured using the EPID and that measured with the other dosimeters for field sizes lower than ۸×۸ cm۲. In the energy of ۶ MV, the gamma passing rates (۳%/۳ mm) between EPID and diode profile were ۹۸%, ۹۸%, ۹۵%, ۹۴%, ۹۳%, and ۹۴% for ۱×۱, ۲×۲, ۳×۳, ۴×۴, ۵×۵, and ۱۰×۱۰ cm۲, respectively. The measured penumbra width with EPID was higher compared to that measured by the diode dosimeter for both energies. Conclusion: The EPID can measure the dosimetric parameters in small photon fields, especially for beam profiles and penumbra measurements.
کلیدواژه ها:
Computer-Assisted ، Electronic Portal Imaging Device ، Photons ، Radiation dosimetry ، Radiotherapy Planning ، Small Field
نویسندگان
Mohammad Haghparast
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Wrya Parwaie
Department of Medical Physics, Faculty of Paramedical Sciences, Ilam University of Medical Sciences, Ilam, Iran
Mohsen Bakhshandeh
Department of Radiology Technology, School of Allied Medical Sciences, Shahid Beheshti University of Medical Science, Tehran, Iran
Nina Tuncel
Radiation Oncology Department, School of Medicine, Akdeniz University, Antalya, Turkey
Seied Rabi Mahdavi
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :