Percutaneous Sacroiliac Screw Fixation: A Modified Screw Insertion Method Using Just ۲ Fluoroscopy Views
محل انتشار: مجله استخوان و جراحی عمومی، دوره: 12، شماره: 8
سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 210
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_TABO-12-8_005
تاریخ نمایه سازی: 14 مرداد 1403
چکیده مقاله:
Objectives: Percutaneous sacroiliac screw fixation (PSSF) is a well-defined method of surgery to fix unstable fractures of the pelvic ring with fewer post-surgical complications. However, the complex anatomy of the mentioned area makes PSSF a formidable challenge. The present study aimed to investigate a modified screw insertion method using two views of fluoroscopy X-ray instead of the prior three views to reduce the duration of operations and radiation exposures.Methods: The present study was performed on ۱۰ radiopaque plastic pelvic models (including ۲۰ half pelvis) during simulated surgical procedures. Of the ۲۰ screws, ۱۰ were inserted using the conventional method with the navigation of three fluoroscopy views (Group A). The remaining ۱۰ were inserted using the modified method with the navigation of two fluoroscopy views, including just the outlet and inlet views, without taking the lateral view, based on our theory and order of fluoroscopy (Group B). Following screw insertion, the accuracy of screw locations was evaluated using a computed tomography (CT) scan, and the duration of operations and radiation exposures were compared between the two surgery methods at the end of the study.Results: In both groups, nine screws (۹۰%) were located correctly, and one screw (۱۰%) perforated the anterior wall of the first sacral vertebra. The mean±SD of the duration of radiation exposure in groups A and B was ۶.۱±۱.۰ min and ۴.۲±۰.۱ min, respectively (P=۰.۰۱). Moreover, the mean±SD of operation duration in group A was ۴۵.۷±۵.۸ min, but this value in group B was ۳۵.۵±۴.۵, which showed a significant decrease in operation duration (P=۰.۰۴).).Conclusion: PSSF using a modified screw insertion method with just two fluoroscopy views not only had similar accuracy to conventional methods but also could decrease operation time and the following radiation exposure. Level of evidence: IV
کلیدواژه ها:
نویسندگان
Farshid Dehkhoda
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Alireza Manafi Rasi
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Reza Zandi
Department of Orthopedics, Taleghani Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Maryam Abedi
Department of Pathology, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
Seyed Shayan Ebadi
Department of Orthopedics, Shahid Beheshti University of Medical Sciences, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :