Using Electro-peroxone Process to Remediate Soil Contaminated with Phenol

سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 148

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJEE-16-1_001

تاریخ نمایه سازی: 31 تیر 1403

چکیده مقاله:

Industrial processes are among human activities that cause production of a large volume of wastewater containing organic pollutants such as phenol and its derivatives. Soil remediation is crucial for enhancing environmental quality for both humans and other living organisms. This study investigate the use of an electro-peroxone system to remove environmental pollutants from soil. In conjunction with ozonation, the study employed electrochemically generated hydrogen peroxide using a carbon electrode, addressing concerns about transportation and storage. Experiments were structured using response surface methodology (RSM) with three variables: ozone dosages ranging from ۴ to ۸ l/h, initial pollutant concentrations from ۲۰ to ۵۰ mg/kg, and treatment durations between ۷ and ۱۴ days. The effectiveness of phenol removal from soil was assessed by applying a consistent voltage of ۲ V/cm to the soil samples in all experiments. Results revealed a negative correlation between initial pollutant concentration and ozone consumption and a positive correlation between treatment duration and pollutant removal efficiency. Optimal removal efficiency occurred with a ۱۴-day treatment duration, an ۸ l/h ozone dosage, and a ۲۰ mg/kg initial pollutant concentration. The electro-peroxone system's application indicates its potential as a sustainable, eco-friendly, and cost-effective approach to soil remediation for pollution.

کلیدواژه ها:

نویسندگان

E. Faghih Nasiri

Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran

F. Qaderi

Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran

S. M. Rahmaninezhad

Faculty of Civil Engineering, University of Texas Rio Grande Valley, Texas, USA

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Song B, Zeng G, Gong J, Liang J, Xu P, ...
  • Thomé A, Reginatto C, Vanzetto G, Braun AB. Remediation Technologies ...
  • El-Eswed BI, Yousef RI, Alshaaer M, Hamadneh I, Al-Gharabli SI, ...
  • Malamis S, Katsou E. A review on zinc and nickel ...
  • Xu S, Guo S, Wu B, Li F, Li T. ...
  • Almansoory AF, Hasan HA, Idris M, Abdullah SRS, Anuar N. ...
  • Zoqi MJ, Rasooli MA, Khataei B, Doosti MR. Efficiency of ...
  • In persian. URL: https://journals.tums.ac.ir/ijhe/article-۱-۶۷۲۰-en.pd ...
  • Zoqi MJ, Ayobi M, Khataei B. Efficiency of various binders ...
  • Annamalai S, Santhanam M, Sundaram M, Curras MP. Electrokinetic remediation ...
  • Guedes P, Mateus EP, Couto N, Rodríguez Y, Ribeiro AB. ...
  • Ikehata K, Jodeiri Naghashkar N, Gamal El-Din M. Degradation of ...
  • Wang H, Bakheet B, Yuan S, Li X, Yu G, ...
  • Eckenfelder W. Industrial water pollution control. ۱۹۸۹ ...
  • Glaze WH. Reaction products of ozone: a review. Environmental Health ...
  • Bryant EA, Fulton GP, Budd GC. Disinfection alternatives for safe ...
  • Chelme-Ayala P, El-Din MG, Smith DW. Kinetics and mechanism of ...
  • Rubin MB. The history of ozone. The Schönbein period, ۱۸۳۹–۱۸۶۸. ...
  • Yuan S, Li Z, Wang Y. Effective degradation of methylene ...
  • Darvishi Cheshmeh Soltani R, Rezaee A, Khataee A. Combination of ...
  • Li Z, Yuan S, Qiu C, Wang Y, Pan X, ...
  • Wang H, Mustafa M, Yu G, Östman M, Cheng Y, ...
  • Doi: ۱۰.۱۰۱۶/j.chemosphere.۲۰۱۹.۰۶.۲۰ ...
  • Bakheet B, Yuan S, Li Z, Wang H, Zuo J, ...
  • Von Gunten U. Ozonation of drinking water: Part I. Oxidation ...
  • Yao W, Wang X, Yang H, Yu G, Deng S, ...
  • Doi: ۱۰.۱۰۱۶/j.watres.۲۰۱۵.۱۱.۰۲ ...
  • Henrique JMM, Isidro J, Saez C, Lopez‐Vizcaíno R, Yustres A, ...
  • Reddy KR, Darko-Kagya K, Al-Hamdan AZ. Electrokinetic Remediation of Chlorinated ...
  • Proietto F, Khalil A, Maouch W, Galia A, Scialdone O. ...
  • ASTM International, W.C., PA, Astm Standard D۴۹۷۲, Standard Test Methods ...
  • ASTM International, W.C., PA, Astm Standard D۴۳۱۸, Standard Test Methods ...
  • ASTM International, W.C., PA, Astm Standard D۷۹۲۸, Standard Test Method ...
  • ASTM International, W.C., PA, Astm Standard D۲۴۸۷, Standard Practice for ...
  • EPA (Environmental Protection Agency), Phenolics (Spectrophotometric, Manual ۴-Aap with Distilution)-Method ...
  • Andrade DC, Dos Santos EV. Combination of electrokinetic remediation with ...
  • Liu J, Zhao L, Li Y, Huang M, Tong X, ...
  • Doi: ۱۰.۱۰۱۶/j.eti.۲۰۲۳.۱۰۳۴۸ ...
  • Porter P. A comparison of ozonation systems with respect to ...
  • Dubey S, Joshi A, Trivedi R, Pal D, Prajapati AK. ...
  • Hou M, Chu Y, Li X, Wang H, Yao W, ...
  • Wen D, Fu R, Li Q. Removal of inorganic contaminants ...
  • نمایش کامل مراجع