A Protection for Loss of Field in Synchronous Generator in Presence of Series Compensation Capacitor

سال انتشار: 1403
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 64

فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJE-37-9_015

تاریخ نمایه سازی: 23 خرداد 1403

چکیده مقاله:

In this research, a new approach to safeguard against Loss of Field (LOF) in a synchronous generator, in the presence of a series compensation capacitor, is introduced. LOF can lead to detrimental effects on both the generator and the power network. Impedance-based negative and positive offset MHO relays are employed for the rapid recognition of LOE occurrences in the network. However, issues arise when a series compensation capacitor is integrated into the system, causing maloperation of the protection relays. The introduction of the series compensation capacitor alters the total impedance value, necessitating adjustments to the relay settings for precise functionality. The variation in the overall impedance of the system leads to the underreaching and overreaching of a relay. The study provides detailed explanations and comparisons of both types of MHO relays, along with their respective settings. A simulation is applied in DIGSILENT to assess the effect of series compensation capacitors on offset MHO (negative and positive) relay LOF protection. Ultimately, the article concludes by summarizing the pros and cons of both relay schemes.

نویسندگان

H. Noori

Faculty of Electrical and Computer Engineering, Semnan University, Semnan, Iran

H. Yaghobi

Faculty of Electrical and Computer Engineering, Semnan University, Semnan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Parivar H, Darabi A. Design and Modeling of a High-Speed ...
  • Ebadi A, Hosseini S, Abdoos A. A new restricted earth ...
  • Yaseen LA, Ebadi A, Abdoos AA. Discrimination between Inrush and ...
  • Bkhaitawi A, Abdoos A, Ebadi A. Presenting an adaptive restraint ...
  • Klempner G, Kerszenbaum I. Operation and maintenance of large turbo-generators: ...
  • Barhate TS, Thakre MP, editors. Generator LOE protection by using ...
  • Mason C. A new loss-of-excitation relay for synchronous generators. Transactions ...
  • Berdy J. Loss of excitation protection for modern synchronous generators. ...
  • Zellagui M, Chaghi A. Impact of series compensation (SC) on ...
  • Ebrahimi SY, Ghorbani A. Performance comparison of LOE protection of ...
  • Mati A, Bentarzi H, editors. Impact of STATCOM on generator ...
  • Sidhu TS, Khederzadeh M. Series compensated line protection enhancement by ...
  • Moravej Z, Jazaeri M, Gholamzadeh M. Optimal coordination of distance ...
  • de Souza Pinheiro PHB, Santos MHMN, Colombini AC, França BW, ...
  • Gorgani Firouzjah K. Fault Location on Compensated Transmission Lines without ...
  • Abbasi M, Shayestehkhah H, Tousi B. Application of an additive ...
  • Ziegler G. Numerical distance protection: principles and applications: John Wiley ...
  • Jena P, Pradhan AK. A positive-sequence directional relaying algorithm for ...
  • Azari M. Zone-۳ impadance reach setting of distance relays by ...
  • Yahiou A, Mellah H, Bayadi A. Inrush current reduction by ...
  • Biswal M, Pati BB, Pradhan AK. Adaptive distance relay setting ...
  • Zare H, Yaghobi H, Alinejad‐Beromi Y. Adaptive concept of controlled ...
  • Noroozi N, Alinejad‐Beromi Y, Yaghobi H. Fast approach to detect ...
  • Yaghobi H. Fast predictive technique for reverse power detection in ...
  • Yaghobi H. Impact of static synchronous compensator on flux‐based synchronous ...
  • نمایش کامل مراجع