Strength Properties of Polymer Reactive Powder Concrete with Waste Materials
محل انتشار: ژورنال مهندسی عمران، دوره: 9، شماره: 8
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 94
فایل این مقاله در 21 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_CEJ-9-8_009
تاریخ نمایه سازی: 2 اردیبهشت 1403
چکیده مقاله:
Reactive powder concrete, or RPC, outperforms conventional or even high-performance concrete in terms of ultra-high strength and better durability. Several buildings were destroyed in Iraq, and recycling the garbage from these buildings can significantly help reduce waste and environmental pollution as well as serve as a source of aggregate for use in new construction. Reusing garbage and using sustainable building materials are now crucial environmental challenges, so this study aimed to replace the natural fine aggregate, NFA, used in preparations of polymer reactive powder concreter, "PRPC" with recycled aggregates, or RA, from crushed old concrete, COC, in order to make PRPC production more environmentally and sustainably friendly. In this study, RPC is modified by adding styrene butadiene rubber (SBR), a polymer, to the original mixture at a ratio of ۱۳% by weight of cement. This study sought to determine the effect of using COC as recycled fine aggregate (RFA) on the compressive, splitting, and flexural strengths of PRPC. The main objective of this investigation is to study the effect of oil (water, new oil, and waste engine oil) on the compressive and tensile strengths of PRPC with COC and to compare the behavior with that of a control mix (PRPC with NFA). The mixtures were prepared using six different percentages of RFA, replacing ۰, ۲۰, ۴۰, ۶۰, ۸۰, and ۱۰۰% NfA. After ۲۸ days, the six mixes were divided into three groups. The first was still being cured in water, W; the second in waste engine oil, WEO; and the third in kerosene oil, KO. The results showed that using COC as RFA in PRPC was viable, and according to this investigation, the mix with ۴۰% COC replacement with NFA provides the highest values of compressive strength, tensile strength, and flexural strength before and after exposure to liquids (water, new oil, and waste engine oil). Doi: ۱۰.۲۸۹۹۱/CEJ-۲۰۲۳-۰۹-۰۸-۰۹ Full Text: PDF
کلیدواژه ها:
Used Engine Oil ، Modified Reactive Powder Concrete ، Recycle Fine Aggregates ، Garbage ، Crushed Concrete ، Kerosene.
نویسندگان
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :