Function Assessment of a Fabricated Artificial Vascular Graft in Sheep Carotid Artery

سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 30

فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_ZUMS-31-148_004

تاریخ نمایه سازی: 20 فروردین 1403

چکیده مقاله:

Background and Objective: In the field of vascular surgery, the use of tissue-engineered vascular grafts is advancing and new synthetic tissues are being utilized to replace damaged blood vessels. These synthetic vessels, made through tissue engineering techniques, must mimic the shape and mechanical properties of native vessels. This study was performed to assess the function of an artificial vascular graft in an animal model. Materials and Methods: The evaluation of artificial vessels was carried out on rat and sheep models. The artificial vascular scaffolds were made of Polyethylene terephthalate (PET), Polyurethane (PU), and Polycaprolactone (PCL) polymers. In the first phase, the fabricated scaffolds were implanted in rats and after ۴۵ days, the grafts were removed and evaluated pathologically. In the second phase, the structures were implanted into the carotid arteries of sheep. Doppler ultrasound and angiography imaging were done to assess changes in carotid blood flow. Eleven months later, the artificial grafts and surrounding tissues were removed and evaluated pathologically. Results: In the rat samples, no hypodermic infections, systemic inflammation, or fibrosis of adjacent tissues were observed. In the sheep samples, no local or systemic complications were reported one week after surgery. No complications were seen after ۱۱ months in the two sheep that received PCL/PU grafts. In contrast, ultrasound evaluation showed thrombosis in the two other sheep that received PET/PU/PCL grafts. Conclusion: This study shows that the implanted artificial vessel used in sheep carotid arteries has a favorable patency rate and satisfactory clinical results, and in terms of mechanical properties, it may be a good candidate for vascular replacement.

نویسندگان

Gholamhossein Kazemzadeh

Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

Hosein Kazemi Mehrjerdi

Dept. of Clinical Sciences, Faculty of Veterinary Medicine, Ferdowsi University of Mashhad, Mashhad, Iran

Masoud Rajabioun

Dept. of Clinical Sciences, Faculty of Veterinary Medicine, Ferdowsi University of Mashhad, Mashhad, Iran

Seyed Ali Alamdaran

Dept. of Radiology, Faculty of Medical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran

Davod Mohebbi-Kalhori

Dept. of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Iran

Nafiseh Jirofti

Dept. of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Iran

Samaneh Abolbashari

Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

Reza Taheri

Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Madhavan K, Elliot W, Tan Y, Monnet E, Tan W. ...
  • Abdulhannan P, Russell D, Homer-Vanniasinkam S. Peripheral arterial disease: a ...
  • Singh G, Cordero J, Wiles B, et al. Development of ...
  • Fukunishi T, Ong CS, Yesantharao P, et al. Different degradation ...
  • نمایش کامل مراجع