Nickel sulfide-based composite as electrodes in electrochemical sensors: A review
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 278
فایل این مقاله در 13 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JRCC-5-14_006
تاریخ نمایه سازی: 6 اسفند 1402
چکیده مقاله:
Nickel sulfide (NiS) is an extremely a transition metal sulfide with great potential use as a sensor material because of its exceptional conductivity and stability. Herein, we present first, the all of synthesis of NiS into sensor and biosensor. Electrochemical sensor, Due to the fact that disposal to electrolyte during electrochemical impact can rapidly deform NiS, lowering its electroactivity and measurement repeatability, a method for effectively integrating NiS into sensors is crucial. Then, the main focus of this review is the recent advancements in sensor systems that utilize NiS and its composites. The article discusses the correlation between sensing performance and electrode construction strategies, and identifies shortcomings and limitations in the current applications of these sensors. Based on this analysis, the authors suggest potential future directions and areas for further research in the development of NiS-based sensors. This study focused on developments in NiS-based sensor systems and their composites throughout the past articles. The article investigates the correlation between the way electrodes are made and the effectiveness of the sensors they produce. On this basis, we discuss the scope for future of NiS-based sensors and offer additional directions.Nickel sulfide (NiS) is an extremely a transition metal sulfide with great potential use as a sensor material because of its exceptional conductivity and stability. Herein, we present first, the all of synthesis of NiS into sensor and biosensor. Electrochemical sensor, Due to the fact that disposal to electrolyte during electrochemical impact can rapidly deform NiS, lowering its electroactivity and measurement repeatability, a method for effectively integrating NiS into sensors is crucial. Then, the main focus of this review is the recent advancements in sensor systems that utilize NiS and its composites. The article discusses the correlation between sensing performance and electrode construction strategies, and identifies shortcomings and limitations in the current applications of these sensors. Based on this analysis, the authors suggest potential future directions and areas for further research in the development of NiS-based sensors. This study focused on developments in NiS-based sensor systems and their composites throughout the past articles. The article investigates the correlation between the way electrodes are made and the effectiveness of the sensors they produce. On this basis, we discuss the scope for future of NiS-based sensors and offer additional directions.
کلیدواژه ها:
نویسندگان
Maryam Irandoost
Department of Materials and Metallurgical Engineering, Amirkabir University of Technology, Tehran, Iran
Beena Kumari
Department of Pharmaceutical Sciences, Indira Gandhi University, Meerpur, Rewari, Haryana, India -۱۲۳۴۰۱
Tuyen Truong
Applied Physical Chemistry Laboratory (APCLAB), VNUHCM-University of Science, Ho Chi Minh City, Vietnam
Bhishma Karki
Department of Physics, Tri-Chandra Multiple Campus, Tribhuvan University, Kathmandu ۴۴۶۰۰, Nepal
Md Rahimullah Miah
Department of IT in Health, North East Medical College and Hospital, Affiliated with Sylhet Medical University, Sylhet, Bangladesh
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :