Validation of Transcutaneous Bilirubinin Comparison with Serum Bilirubin for the Detection of Hyperbilirubinemia in Neonates

سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 132

متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJHS-3-3_008

تاریخ نمایه سازی: 29 بهمن 1402

چکیده مقاله:

Background: Neonatal hyperbilirubinemia is a common and dangerous complication that should be diagnosed as soon as possible.This study aimed to validate transcutaneous bilirubin in comparison with serum bilirubin for the detection of hyperbilirubinemiain neonates.Methods: This cross-sectional study was conducted in ۲۸۰ infants with jaundice who were referred to Bahar Hospital in Shahroud in ۲۰۱۶. The serum bilirubin was measured by the photometric method. Three measurements of transcutaneous bilirubin were performed (by Bilichek) for each infant, and their average was recorded. The sensitivity and specificity of transcutaneous bilirubin measurements were assessed in comparison with the measurements using laboratory methods as the gold standard using ROC analysis.Results: Of the ۲۸۰ neonates, ۱۵۳ (۵۴.۶%) were male. The mean age of the patients was ۱۱.۷۷ ± ۴.۶ days. The mean bilirubin level was ۱۶.۹ ±۱۰.۱ mg/dl measured usingthe BiliChek method and ۱۵.۳ ± ۹.۵ mg/dl using the laboratory method, and the difference was significant (p<۰.۰۴). The sensitivity and specificity of the BiliChek measurements in neonates were ۸۸.۳% and ۷۳.۶%, respectively. According to the findings from the ROC curve, the cut off point was determined to be more than ۱۴.۷ units (surface area below the curve (AUC) = ۸۷.۵%).Conclusion: The results of this study showed that the accuracy (sensitivity and specificity) of the BiliChek device was good and can be used to measure the neonatal bilirubin.Background: Neonatal hyperbilirubinemia is a common and dangerous complication that should be diagnosed as soon as possible.This study aimed to validate transcutaneous bilirubin in comparison with serum bilirubin for the detection of hyperbilirubinemiain neonates. Methods: This cross-sectional study was conducted in ۲۸۰ infants with jaundice who were referred to Bahar Hospital in Shahroud in ۲۰۱۶. The serum bilirubin was measured by the photometric method. Three measurements of transcutaneous bilirubin were performed (by Bilichek) for each infant, and their average was recorded. The sensitivity and specificity of transcutaneous bilirubin measurements were assessed in comparison with the measurements using laboratory methods as the gold standard using ROC analysis. Results: Of the ۲۸۰ neonates, ۱۵۳ (۵۴.۶%) were male. The mean age of the patients was ۱۱.۷۷ ± ۴.۶ days. The mean bilirubin level was ۱۶.۹ ±۱۰.۱ mg/dl measured usingthe BiliChek method and ۱۵.۳ ± ۹.۵ mg/dl using the laboratory method, and the difference was significant (p<۰.۰۴). The sensitivity and specificity of the BiliChek measurements in neonates were ۸۸.۳% and ۷۳.۶%, respectively. According to the findings from the ROC curve, the cut off point was determined to be more than ۱۴.۷ units (surface area below the curve (AUC) = ۸۷.۵%). Conclusion: The results of this study showed that the accuracy (sensitivity and specificity) of the BiliChek device was good and can be used to measure the neonatal bilirubin.

نویسندگان

Afsaneh Sadeghian ۱

۱. Dept. of Pediatric, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran.

Ghazale Neymati ۲

۲. General Practitioner, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran.

Elahe Yahyaei ۳

۳. Dept. of Nursing, Shahroud University of Medical Sciences, Shahroud, Iran.