Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at ۶ and ۱۸ MV Linac Energies using Monte Carlo Simulation Methods
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 9، شماره: 1
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 55
فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-9-1_005
تاریخ نمایه سازی: 1 بهمن 1402
چکیده مقاله:
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at different depths and field sizes.Objective: Determining correction factors (KNR and KNCSF) recommended recently for small field dosimetry formalism by American Association of Physicists in Medicine (AAPM) for different detectors at ۶ and ۱۸ MV photon beams.Methods: EGSnrc Monte Carlo code was used to calculate the doses measured with different detectors located in a slab phantom and the recommended KNR and KNCSF correction factors for various circular small field sizes ranging from ۵-۳۰ mm diameters. KNR and KNCSF correction factors were determined for different active detectors (a pinpoint chamber, EDP-۲۰ and EDP-۱۰ diodes) in a homogeneous phantom irradiated to ۶ and ۱۸ MV photon beams of a Varian linac (۲۱۰۰C/D). Results: KNR correction factor estimated for the highest small circular field size of ۳۰ mm diameter for the pinpoint chamber, EDP-۲۰ and EDP-۱۰ diodes were ۰.۹۹۳, ۱.۰۲۰ and ۱.۰۵۴; and ۰.۹۹۲, ۱.۰۵۴ and ۱.۰۰۵ for the ۶ and ۱۸ MV beams, respectively. The KNCSF correction factor estimated for the lowest circular field size of ۵ mm for the pinpoint chamber, EDP-۲۰ and EDP-۱۰ diodes were ۰.۹۹۴, ۱.۰۲۳, and ۱.۰۴۰; and ۱.۰۰۰, ۱.۰۱۴, and ۱.۰۲۲ for the ۶ and ۱۸ MV photon beams, respectively.Conclusion: Comparing the results obtained for the detectors used in this study reveals that the unshielded diodes (EDP-۲۰ and EDP-۱۰) can confidently be recommended for small field dosimetry as their correction factors (KNR and KNCSF) was close to ۱.۰ for all small field sizes investigated and are mainly independent from the electron beam spot size.
کلیدواژه ها:
نویسندگان
S A Rahimi
PhD Candidate, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
B Hashemi
Associate Professor, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
S R Mahdavi
Associate Professor, Department of Medical Physics, Faculty of Medicine, Iran University of Medical Sciences, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :