Non-Invasive Flow Ratio (NiFR) Measurement based on Angiography Images
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 11، شماره: 6
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 73
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-11-6_003
تاریخ نمایه سازی: 30 دی 1402
چکیده مقاله:
Background: Fractional flow reserve (FFR) is a gold standard to assess the impact of stenosis on the blood flow. The FFR method enhances diagnostic accuracy, lessens the need for stenting, and reduces costs. However, FFR is used in less than ۱۰% of percutaneous coronary intervention (PCI) procedures because it needs pressure wires to measure the distal and proximal pressures and adenosine to create hyperemic conditions. Pressure-wire-based FFR measurement is, therefore, expensive and invasive.Objective: This study aims to introduce a new approach on the basis of ۳D coronary angiography and the Thrombolysis in Myocardial Infarction (TIMI) frame count for fast computation of FFR in patients with coronary artery disease. Material and Methods: In this simulation study, we herein introduce Non-Invasive Flow Ratio drawing upon CFD to measure FFR based on coronary angiography images with less run time. In this study, ۳D geometry was created based on coronary angiography images. The mean volumetric flow rate was calculated using the TIMI frame count. FFR calculated based on CFD was compared with pressure-wire-based FFR and NiFR was calculated in ۸۵ patients. Results: The NiFR (r = ۰.۷۳۸, p < ۰.۰۰۱) exhibited a strong correlation with pressure-wire-based FFR. The result indicated that FFR was higher than ۰.۸ in the arteries with non-significant stenosis and lower than ۰.۸ in the arteries with significant stenosis.Conclusion: The computational simulation of FFR and hemodynamic parameters such as pressure drop is a safe, efficient, and cost-effective method to evaluate the severity of coronary stenosis.
کلیدواژه ها:
نویسندگان
- -
MD, Department of Cardiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
- -
MD, Department of Cardiology, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
- -
MD, Department of Cardiovascular Research, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
- -
MSc, Department of Mechanical Engineering, Tarbiat Modarres University, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :