Newly designed instrument for desalination: Comparison with dialysis bag

سال انتشار: 1385
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 35

فایل این مقاله در 5 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_ARCHRAZI-61-3_007

تاریخ نمایه سازی: 6 دی 1402

چکیده مقاله:

All desalination methods which are currently used have limitations. A newly designed instrument by Zare A.M. was tested and compared with currently used method in Razi Vaccine and Serum Research Institute(RVSRI). Samples of anti snake venom for desalination was provided by department of anti-serum, RVSRI. Parameters included in this study were time and water consumption during desalination process. PH, conductivity, Total protein, potency and dry weight of samples. Results reveals that complete desalination process by our newly designed instrument consumes only ۴.۳۰ hours and ۸۰ litters of purified water as compared to currently used method of dialysis bag with average of ۱۲۰ hours of time and ۱۹۲۰ litters of purified water(P