Correlation of Depth of Anesthesia with Hemodynamic Parameters in Patients Undergoing Elective Abdominal Surgery

سال انتشار: 1394
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 55

فایل این مقاله در 5 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JGBFNM-12-2_003

تاریخ نمایه سازی: 20 آذر 1402

چکیده مقاله:

Background and Objective: The usual method of assessing depth of anesthesia, which is not sensitive and specific enough, is measuring hemodynamic parameters, autonomic changes and subjective symptoms including movement, sweating and lacrimation. This study aimed to determine the relationship between the depth of anesthesia and hemodynamic indices. Material and Methods: This correlational study was conducted on ۵۷ patients undergoing elective hernia surgery in Shahid Beheshti Hospital ,Sabzevar in summer ۲۰۱۴.  An identical anesthesia technique was used for all patients.  Depth of anesthesia was monitored quantitatively by bispectral index (BIS) at ۵-minute intervals, with simultaneous recording of heart rate and blood pressure. We analyzed the data using Anova and correlation coefficient. Results: The mean age was ۴۵.۵۴±۱۳.۴۶. The patients were males (n=۳۶) and females (n= ۲۱).   Only ۵۹.۶ % of the patients experienced a normal depth of anesthesia. Hemodynamic parameters were not significantly correlated with anesthetic depth except for heart rate in the first ۵ minutes (P= ۰.۰۱۳). Conclusion: Given that hemodynamic parameters have some limitations in determining the acceptable depth of anesthesia, we recommend using the monitors based on brain signal processing.