Anatomical Information Quality Control of a Radiotherapy Treatment Planning System
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 20، شماره: 4
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 118
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-20-4_002
تاریخ نمایه سازی: 24 مهر 1402
چکیده مقاله:
Introduction: To determine radiotherapy accuracy and prevent treatment errors, quality assurance is crucial during the planning phase of radiation therapy. Therefore, the goal of this study was to create criteria for the routine quality control assessment of radiation treatment planning systems TPS to assess their effectiveness and accuracy. Material and Methods: In this study, we used a Prowess Panther treatment planning system TPS (version ۵.۵۱), a Siemens model Somatom Confidence computed tomography simulator, an anthropomorphic Alderson-Rando phantom, and a density phantom made from a CTDI head phantom by inserting plugs that mimicked human tissue. The TPS features include hardware, transmitted CT images (anatomical information), and key software operations; however, in this investigation, we focused exclusively on the tests involving anatomical information. Results: The Prowess Panther RTPS version ۵.۵۱ workstation consistently met the requisite quality where all results of the radiation treatment planning systems (Prowess Panther RTPS) anatomical information tests were satisfactory and acceptable. Conclusion: By averting several radiation-related events, the recommendations for TPS CT image quality control testing made in this study will assist to increase the safety and effectiveness of cancer radiotherapy.
کلیدواژه ها:
نویسندگان
Rehab Abd Elaziz
Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt.
Ibrahim awad
Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, Mansoura University, Egypt
alia ahmed
Clinical Oncology &Nuclear Medicine Dept., Faculty of Medicine, Mansoura University, Mansoura, Egypt.
Ahmed oraby
Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :