Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 16، شماره: 4
سال انتشار: 1398
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 125
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-16-4_006
تاریخ نمایه سازی: 5 شهریور 1402
چکیده مقاله:
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise ratio and can be related to image quality. The aim of this study was to evaluate the influence of EI on image quality and radiation dose for the posterior anterior (PA) chest radiography. Material and Methods: This study was conducted in three phases, namely pre-optimization, experimental, and post-optimization. A total of ۶۰ patients that could fulfill the inclusion and exclusion criteria for the PA chest radiography were recruited. The radiographic technical parameters, dose area product, and EI were recorded. Radiographs were printed and evaluated by two recruited radiologists using the modified evaluation criteria established by the Commission of European Communities in ۱۹۹۶. Results: Statistical analysis using Spearman’s Rho Correlation showed an insignificant relationship between EI and image quality for the PA chest radiography (p >۰.۰۵). Conversely, there was a significant relationship between EI and radiation dose (p <۰.۰۵). Conclusion: TheEI can be used as an indirect measure of image quality and radiation dose. The EI does not directly determine image quality since the radiographic technique and parameters used can affect image quality. Although EI can be used as a measure of radiation dose, it cannot provide an accurate measurement of the radiation received by the patient.
کلیدواژه ها:
نویسندگان
Soo-Foon Moey
International Islamic University Malaysia
Mohamad Asri Fatin Naimah
International Islamic University Malaysia
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :