Drill- and suction generated noise levels in mastoid surgery
سال انتشار: 1387
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 146
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJOTO-19-50_005
تاریخ نمایه سازی: 28 مرداد 1402
چکیده مقاله:
Introduction: It has been recognized that noise levels generated during ear surgery may cause sensorineural hearing loss. However, there is a controversy about the main factor that may cause such hearing threshold alternations: drilling, suction or both of them. The purpose of this investigation was to measure the air-conduction noise levels generated by common drills, burrs and suction irrigators in mastoid surgery.Materials and Methods: Our evaluations were carried out in two states: isolated temporal bones (cadavers) and intraoperative recordings. Preliminary drillings were made on ۱۰ cadavers, and intensity and frequency analysis of common diamond and cutting burrs were performed. Then, the noise levels generated by drilling, suction irrigation and simultaneous drilling & suction irrigation were measured from ۱۵ patients under radical modified mastoidectomy. Data were analyzed by SPSS ۱۱ software and ۰.۰۵ value was regard as significant level.Results: The average noise levels of drilling ranged from ۸۳ to ۹۵ dB SPL, varying with burr used. Cutting burrs were found to be up to more intense than diamond burrs. Mean suction irrigation noise levels ranged from ۷۷.۴۵ to ۷۸.۶۵ dB SPL. The average of "intraoperative drilling" and "simultaneous drilling and suction irrigation" generated noise levels were ۸۷.۱۴ and ۸۶.۲۶ dB SPL, respectively. The comparison of resultant noise levels between cadaver and under operation situations was not statistically significant.Conclusion: Our results showed that the main factor contributing the highest noise level is drilling which is predominately apparent in cutting burrs. Exposure to these noise levels may account for shifts in the hearing thresholds.
کلیدواژه ها:
نویسندگان
Arash Bayat
Ahwaz, PO Box ۱۱۹۸-۶۱۵۵۵
Hesamoddin Emamdjomeh
Member of the scientific board of Audiology Department, Iran University of Medical Sciences.
Mohammad Farhadi
Professor, member of the scientific staff of the Ear, Throat and Nose Department, Iran University of Medical Sciences
Ahmad Daneshi
Professor, member of the scientific staff of the Ear, Throat and Nose Department, Iran University of Medical Sciences
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :