On the Sensitivity Increasing of a Capacitive Bio Disease Detector
محل انتشار: دومین کنگره بین المللی علوم و فناوری نانو
سال انتشار: 1387
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 897
متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICNN02_086
تاریخ نمایه سازی: 27 شهریور 1391
چکیده مقاله:
Nowadays scientists are chasing the vision of making miniaturized MEMS based specifically designed and manufactured biochips based on an array of micro cantilevers, which can detect several routinely diagnosed diseases which are detected simultaneously in the clinical laboratory [1].Sensing of tip deflection of a micro-cantilever which is subjected to smoothly flow of infected blood is one of the concepts of the diagnosis. This deflection is related to the antigens concentration in blood. These sets have been employed in monitoring certain diseases such as cancer and detecting specific chemical and biological infections [1]. As specific binding of bio-molecules occurs on the surface of a micro-cantilever, intermolecular nano mechanical stress induces a bending effect on the cantilever. This is achieved by immobilizing a monolayer of receptor molecules on one side of the cantilever in a liquid environment [2]. Cancer detecting microchips, myoglobin detection sensors, glucose biosensors, and biosensors for coronary heart disease are some application of micro cantilever in the field of disease diagnosis.Some optical sensing methods are used in post designed and investigated samples, but there is a problem that deflection due to presence of antigens is very small (in nanometer) and the sensitivity is low. Therefore in this paper firstly has been tried to increase the sensitivity of the sensor into antigens by use of applying voltage and secondly to dispose a capacitive sensing. Capacitive sensing method [3] is based on the changes of capacity of a planar capacitance due to the adsorption of the antigens
نویسندگان
Mehdi Atashparva
Department of mechanical engineering, university of URMIA ۱۴۵۳, URMIA, IRAN
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :