Light’s Criteria Versus Costa’s Criteria in Differentiating Transudative & Exudative Pleural Effusions
محل انتشار: مجله پزشکی قلب و قفسه سینه، دوره: 11، شماره: 1
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 161
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JCTM-11-1_003
تاریخ نمایه سازی: 20 فروردین 1402
چکیده مقاله:
Introduction: Aim of this study is to compare COSTA’S and LIGHT’S criteria in identifying exudative from transudative pleural effusions.Materials & Methods: A prospective study that is hospital-based was conducted at GHCCD, during Jan ۲۰۱۷ to August ۲۰۱۸ in ۸۰ patients who presented with pleural effusion. Light’s and Costa’s criteria were applied to differentiate them into transudative and exudative effusions.Results: Among the pleural effusions, ۸۳.۷۵% were exudates and ۱۶.۲۵% were transudates. Tuberculous effusion (۴۵%) was the most common among exudates, and chronic kidney disease (۱۰%) was the most common among the transudates. On biochemical analysis of effusions, the mean pleural fluid cholesterol levels were ۷۴.۰۲±۲۰.۵۱mg/dl and ۲۹.۲۳±۷.۴۴mg/dl in exudative and transudative effusions respectively. On ROC analysis, the cut-off value for pleural fluid cholesterol was considered >۵۰mg/dl and <۲۹mg/dl for exudative and transudative effusions respectively. The mean pleural fluid LDH cut-off values on ROC analysis was >۲۳۱U/L for exudative effusions and <۲۳۱U/L for transudative effusions. The sensitivity, specificity, PPV, NPV of Lights criteria observed to be ۱۰۰%, ۶۱.۵%, ۹۳.۰۵% & ۱۰۰% with accuracy of ۹۳.۷۵% whereas the values of Costa’s criteria were ۹۷%, ۹۲%, ۹۸%, ۸۵.۷% with accuracy of ۹۶.۲۵% in differentiating exudates and transudates. P-value was statistically significant for both criteria.Conclusion: Pleural fluid LDH and cholesterol are found to be excellent parameters to differentiate transudates and exudates. Costa’s criteria is simple, convenient with almost equal sensitivity and more specificity in comparison to Light’s criteria, with fewer pleural fluid parameters compared to Light’s criteria.
کلیدواژه ها:
نویسندگان
Padmaja Balla
Department of Pulmonary Medicine, GHCCD, Chinnawaltair, Visakhapatnam, Andhra Pradesh, India.
Koyyana Preethi
Department of Pulmonary Medicine, GHCCD, Chinnawaltair, Visakhapatnam, Andhra Pradesh, India.
Kanakalakshmi K
Department of Pulmonary Medicine, GHCCD, Chinnawaltair, Visakhapatnam, Andhra Pradesh, India.
Vishnu Chaitanya
Department of Pulmonary Medicine, GHCCD, Chinnawaltair, Visakhapatnam, Andhra Pradesh, India.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :