Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
محل انتشار: مجله پزشکی هسته ای ایران، دوره: 29، شماره: 2
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 154
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJNM-29-2_006
تاریخ نمایه سازی: 4 بهمن 1401
چکیده مقاله:
Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy. An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The effect of the collimator slit size and source off-axis position on the sensitivity of the collimator were included in the formula. Results: The analytically calculated sensitivities of the slit collimator were in good agreement with Monte Carlo results according to the Bland-Altman agreement test and Pearson correlation (r =۰.۹۹۸) statistical analysis with . The mean relative error between calculated sensitivities with the derived formula and Monte Carlo was up to ۰.۸%. Moreover, we found that under certain conditions, the established formula is converted to the Anger equation for the pinhole collimator. Conclusion: The analytical formula developed in this research can estimate the slit collimator sensitivity with an acceptable accuracy. The derived closed-form sensitivity formula can be applied in KE collimator design and optimization studies.
کلیدواژه ها:
نویسندگان
Etesam Malekzadeh
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Hossein Rajabi
Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Elisa Fiorina
National Institute of Nuclear Physics, Section of Torino, Torino, Italy
Faraz Kalantari
Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :