Left ventricular ejection fraction by multigated acquisition scan using planar sodium iodide and cadmium-zinc-telluride cameras: a comparison with two-dimensional echocardiography
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 124
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JNMB-11-1_008
تاریخ نمایه سازی: 25 دی 1401
چکیده مقاله:
Objective(s): This study was undertaken to compare the correlation and agreement between Modified Simpson’s method two-dimensional-echocardio-graphy (۲D-echo) and rest multigated acquisition scan (MUGA) using both planar sodium iodide (pNaI) and cadmium-zinc-telluride (CZT) cameras to measure left ventricular ejection fraction (LVEF).Methods: One hundred and nine breast cancer patients monitored for cardiotoxicity underwent ۲D-echo, followed by pNaI and CZT MUGA scans on the same day. LVEF for CZT camera was processed using both automatic and manual processing methods, thus yielding four methods for the LVEF analysis.Results: Significant correlation (p<۰.۰۱) was seen among all four methods, with varied correlation strengths. Moderate correlation was seen between ۲D-echo and both pNaI (r=۰.۵۶) and CZT cameras (automatic r=۰.۵۴, manual r=۰.۵۶). Strong correlation was registered between pNaI and CZT camera (automatic r=۰.۷۲, manual r=۰.۷۱). Bland-Altman limits of agreement among the three scans were wide and suboptimal. The widest limits were -۲۱.۱ to +۱۶.۲ (۳۷%) between ۲D-echo and CZT auto-processing.Conclusion: Any one of the modalities can be used to measure LVEF, however, their results should not be used interchangeably. The same method of measurement is advised for serial scans.
کلیدواژه ها:
نویسندگان
Gouri V G Kumar Das
Department of Nuclear Medicine, Hospital Sultanah Aminah, Johor Bahru, Johor, Malaysia
Chen Siew Ng
Department of Nuclear Medicine, Hospital Sultanah Aminah, Johor Bahru, Johor, Malaysia
Mahayuddin Abdul Manap
Oncological and Radiological Sciences Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Penang, Malaysia
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :